1/10/24, 11:10 AM LANXESS

Data sheet
Pocan B7425 000000
PBT, 20% micro glass beads, injection molding, low tendency to warp, improved surface finish

ISO Shortname: ISO 20028-PBT,GB20,GHMR,11-030

Property Test Condition Unit Standard guide value1


Rheological properties
C Melt volume-flow rate 260 °C; 5 kg cm³/(10 min) ISO 1133-1 35
C Molding shrinkage, parallel 60x60x2; 260 °C / MT 80 % ISO 294-4 2.1
°C; 600 bar
C Molding shrinkage, transverse 60x60x2; 260 °C / MT 80 % ISO 294-4 2.1
°C; 600 bar
Post- shrinkage, parallel 60x60x2; 120 °C; 4 h % ISO 294-4 0.2
Post- shrinkage, transverse 60x60x2; 120 °C; 4 h % ISO 294-4 0.2

Mechanical properties (23 °C/50 % r. h.)


C Tensile modulus 1 mm/min MPa ISO 527-1,-2 3300
C Tensile Stress at break 5 mm/min MPa ISO 527-1,-2 50
C Tensile Strain at break 5 mm/min % ISO 527-1,-2 6.0
C Tensile creep modulus 1h MPa ISO 899-1 3300
C Tensile creep modulus 1000 h MPa ISO 899-1 2700
C Charpy impact strength 23 °C kJ/m² ISO 179-1eU 35
C Charpy impact strength -30 °C kJ/m² ISO 179-1eU 25
C Charpy notched impact strength 23 °C kJ/m² ISO 179-1eA < 10
C Charpy notched impact strength -30 °C kJ/m² ISO 179-1eA < 10
Izod impact strength 23 °C kJ/m² ISO 180-1U 30
Izod impact strength -30 °C kJ/m² ISO 180-1U 20
Izod notched impact strength 23 °C kJ/m² ISO 180-1A < 10
Izod notched impact strength -30 °C kJ/m² ISO 180-1A < 10
Flexural modulus 2 mm/min MPa ISO 178-A 3300
Flexural strength 2 mm/min MPa ISO 178-A 90
Flexural strain at flexural strength 2 mm/min % ISO 178-A 5.0
Flexural stress at 3.5 % strain 2 mm/min MPa ISO 178-A 85
Ball indentation hardness N/mm² ISO 2039-1 160

Thermal properties
C Melting temperature 10 °C/min °C ISO 11357-1,-3 225
C Temperature of deflection under load 1.80 MPa °C ISO 75-1,-2 70
C Temperature of deflection under load 0.45 MPa °C ISO 75-1,-2 170
Vicat softening temperature 50 N; 120 °C/h °C ISO 306 190
C Coefficient of linear thermal expansion, 23 to 55 °C 10-4/K ISO 11359-1,-2 1.0
parallel
C Coefficient of linear thermal expansion, 23 to 55 °C 10-4/K ISO 11359-1,-2 1.0
transverse
https://techcenter.lanxess.com/scp/emea/en/products/type/datasheet.jsp?print=true&ref=&gid=9748&pid=55 1/3
1/10/24, 11:10 AM LANXESS

C Burning behavior UL 94 1.5 mm Class UL 94 HB


C Burning behavior UL 94 0.75 mm Class UL 94 HB
C Oxygen index Method A % ISO 4589-2 23
Thermal conductivity 23 °C W/(m·K) ISO 8302 0.28
Resistance to heat (ball pressure test) °C IEC 60695-10-2 200
Temperature index (Tensile strength) 20000 h °C IEC 60216-1 140
Halving interval (Tensile strength) °C IEC 60216-1 14
Relative temperature index (Tensile °C UL 746B 130
strength)
Temperature index (Tensile impact 20000 h °C IEC 60216-1 130
strength)
Halving interval (Tensile impact strength) °C IEC 60216-1 7.8
Relative temperature index (Tensile °C UL 746B 125
impact strength)
Temperature index (Electric strength) 20000 h °C IEC 60216-1 160
Halving interval (Electric strength) °C IEC 60216-1 11.4
Relative temperature index (Electric °C UL 746B 130
strength)
Glow wire test (GWFI) 2.0 mm °C IEC 60695-2-12 650
Burning behavior US-FMVSS302 ISO 3795 passed

Electrical properties (23 °C/50 % r. h.)


C Relative permittivity 100 Hz - IEC 60250 3.8
C Relative permittivity 1 MHz - IEC 60250 3.6
C Dissipation factor 1 MHz 10-4 IEC 60250 170
C Volume resistivity Ohm·m IEC 62631-3 >1E13
C Surface resistivity Ohm IEC 62631-3 >1E15
C Electric strength 1 mm kV/mm IEC 60243-1 25
C Comparative tracking index CTI Solution A Rating IEC 60112 250

Other properties (23 °C)


C Water absorption (Saturation value) Water at 23 °C % ISO 62 0.4
C Water absorption (Equilibrium value) 23 °C; 50 % RH % ISO 62 0.1
C Density kg/m³ ISO 1183 1440
Bulk density kg/m³ ISO 60 900

Material specific properties


C Viscosity number cm³/g ISO 1628-5 130

Processing conditions for test specimens


C Injection molding-Melt temperature °C ISO 294 260
C Injection molding-Mold temperature °C ISO 294 80

Processing recommendations
Drying temperature circulating air dryer °C - 120
Drying time circulating air dryer h - 4-8
Residual moisture content % Acc. to Karl Fischer 0.00-0.02
Melt temperature (Tmin - Tmax) °C - 250-270
Mold temperature °C - 80-100

https://techcenter.lanxess.com/scp/emea/en/products/type/datasheet.jsp?print=true&ref=&gid=9748&pid=55 2/3
1/10/24, 11:10 AM LANXESS

Notes
1 Typical properties: these are not to be construed as specifications
C These property characteristics are taken from the CAMPUS plastics data bank and are based on the international catalogue of basic data for
plastics according to ISO 10350.

Disclaimer
Disclaimer for commercial products
This information and our technical advice - whether verbal, in writing or by way of trials - are given in good faith but without warranty,
and this also applies where proprietary rights of third parties are involved. Our advice does not release you from the obligation to verify
the information currently provided - especially that contained in our safety data and technical information sheets - and to test our
products as to their suitability for the intended processes and uses. The application, use and processing of our products and the
products manufactured by you on the basis of our technical advice are beyond our control and, therefore, entirely your own
responsibility. Our products are sold in accordance with the current version of our General Conditions of Sale and Delivery.

Test values
Unless specified to the contrary, the values given have been established on standardized test specimens at room temperature. The
figures should be regarded as guide values only and not as binding minimum values. Kindly note that, under certain conditions, the
properties can be affected to a considerable extent by the design of the mould/die, the processing conditions and the coloring.

Processing note
Under the recommended processing conditions small quantities of decomposition product may be given off during processing. To
preclude any risk to the health and well-being of the machine operatives, tolerance limits for the work environment must be ensured by
the provision of efficient exhaust ventilation and fresh air at the workplace in accordance with the Safety Data Sheet. In order to prevent
the partial decomposition of the polymer and the generation of volatile decomposition products, the prescribed processing temperatures
should not be substantially exceeded. Since excessively high temperatures are generally the result of operator error or defects in the
heating system, special care and controls are essential in these areas.

Envalior Deutschland GmbH | DE 40474 DUESSELDORF | Germany