Lanxess - Pocan B7425
Lanxess - Pocan B7425
Data sheet
Pocan B7425 000000
PBT, 20% micro glass beads, injection molding, low tendency to warp, improved surface finish
Thermal properties
C Melting temperature 10 °C/min °C ISO 11357-1,-3 225
C Temperature of deflection under load 1.80 MPa °C ISO 75-1,-2 70
C Temperature of deflection under load 0.45 MPa °C ISO 75-1,-2 170
Vicat softening temperature 50 N; 120 °C/h °C ISO 306 190
C Coefficient of linear thermal expansion, 23 to 55 °C 10-4/K ISO 11359-1,-2 1.0
parallel
C Coefficient of linear thermal expansion, 23 to 55 °C 10-4/K ISO 11359-1,-2 1.0
transverse
https://techcenter.lanxess.com/scp/emea/en/products/type/datasheet.jsp?print=true&ref=&gid=9748&pid=55 1/3
1/10/24, 11:10 AM LANXESS
Processing recommendations
Drying temperature circulating air dryer °C - 120
Drying time circulating air dryer h - 4-8
Residual moisture content % Acc. to Karl Fischer 0.00-0.02
Melt temperature (Tmin - Tmax) °C - 250-270
Mold temperature °C - 80-100
https://techcenter.lanxess.com/scp/emea/en/products/type/datasheet.jsp?print=true&ref=&gid=9748&pid=55 2/3
1/10/24, 11:10 AM LANXESS
Notes
1 Typical properties: these are not to be construed as specifications
C These property characteristics are taken from the CAMPUS plastics data bank and are based on the international catalogue of basic data for
plastics according to ISO 10350.
Disclaimer
Disclaimer for commercial products
This information and our technical advice - whether verbal, in writing or by way of trials - are given in good faith but without warranty,
and this also applies where proprietary rights of third parties are involved. Our advice does not release you from the obligation to verify
the information currently provided - especially that contained in our safety data and technical information sheets - and to test our
products as to their suitability for the intended processes and uses. The application, use and processing of our products and the
products manufactured by you on the basis of our technical advice are beyond our control and, therefore, entirely your own
responsibility. Our products are sold in accordance with the current version of our General Conditions of Sale and Delivery.
Test values
Unless specified to the contrary, the values given have been established on standardized test specimens at room temperature. The
figures should be regarded as guide values only and not as binding minimum values. Kindly note that, under certain conditions, the
properties can be affected to a considerable extent by the design of the mould/die, the processing conditions and the coloring.
Processing note
Under the recommended processing conditions small quantities of decomposition product may be given off during processing. To
preclude any risk to the health and well-being of the machine operatives, tolerance limits for the work environment must be ensured by
the provision of efficient exhaust ventilation and fresh air at the workplace in accordance with the Safety Data Sheet. In order to prevent
the partial decomposition of the polymer and the generation of volatile decomposition products, the prescribed processing temperatures
should not be substantially exceeded. Since excessively high temperatures are generally the result of operator error or defects in the
heating system, special care and controls are essential in these areas.
Date: 19.12.2023
© LANXESS, 2014. All rights reserved. Your use of this site is subject to our terms of use.
https://techcenter.lanxess.com/scp/emea/en/products/type/datasheet.jsp?print=true&ref=&gid=9748&pid=55 3/3