Kitagawa Datasheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 20

Machine Translated by Google

Machine Translated by Google

Thermocouples are widely used in all industrial fields because they can easily provide practical performance as

temperature sensors. Ninomiya Electric Cable Industry manufactures and sells a variety of coated

thermocouple wires with high precision and excellent quality by leveraging the advanced processing technology

we have accumulated since our founding. The coated thermocouple wire has a thermocouple conductor made of

vinyl, silicone

rubber, or fluorine.

A lightweight and flexible thermocouple coated with an insulating material such as resin, glass fiber, silica glass

fiber, or ceramic fiber. Temperature can be easily measured by cutting it to the required length and electrically

connecting one end. can do

A thermocouple that is inexpensive and

convenient. We also offer special coated thermocouple wires that are used under harsh conditions, as well as

coated thermocouple wires that have passed strict inspections and quality tests and have obtained UL standard certification.

We manufacture and sell. In addition,

we also have ``twinter'' connectors exclusively for thermocouples and compensation conductors, so please feel

free to order.
Machine Translated by Google

INDEX
coated thermocouple wire

1. What is a thermocouple? ................................................... ...................... 2

2. Types of thermocouples and conductor materials.................................. 2

3. Shape of coated thermocouple wire................................... ..........3

Four. Classification of use/Insulator and sheath material................... 4

ÿInsulating material and operating temperature range................................... 4

ÿShielding and protective braid/shape........... 4

ÿKey points for selecting coated thermocouple wires................................... .. Four

Five. How to order................................................... .......................... Five

ÿHow to add symbols................................... ....................... Five

Standards for coated thermocouple wires

Vinyl-coated thermocouple wire................................................ ................... 6

Ribbon type vinyl coated thermocouple wire.................................. ..7

Glasses type vinyl coated thermocouple wire.................................................. ..7

Glass Braided Coated Thermocouple Wire................................... ......8

Glass braided coated thermocouple wire (K type, heat-resistant inorganic paint used).... 9

Silica glass braided coated thermocouple wire (K type)................... 9

Ceramic braided coated thermocouple wire (K type)...................10

UL listed coated thermocouple wire.............................. ......11

FEP coated thermocouple wire................................................ ......12

Super extra-fine series................................................... ............13

Thermocouple dedicated connector “Twinter” ................................14

Conductor resistance value, electromotive force value, operating temperature limit...................16

Precautions for use................................... ......17


Machine Translated by Google

1.What is a thermocouple?

Connect both ends of dissimilar metals to create one


Instrument

Create a circuit and create a temperature difference between its two contacts.

When , a thermoelectromotive force is generated in the circuit,

Current flows. using this principle coated thermocouple wire

A temperature sensor is called a thermocouple. Reference temperature junction

Thermocouples include protection tube type thermocouples and sheath heat.

There are different types such as electrocouples, but Ninomiya Electric Wire

In industry, we manufacture and sell coated thermocouple wires.

going.

Temperature measuring contact

2.Type of thermocouple wire and conductor material

Ninomiya Electric Wire Co., Ltd.'s coated thermocouple wires are thermocouple bare wires that comply with JIS C 1602-2015 and ASTM E230 (formerly ANSI MC 96.1).

This product is used as a conductor and is coated with insulation. In addition, since the insulator and sheath are used in a wide range of applications, we will provide compensation.

Conductive wire (JIS C 1610) is referred to, and it is included in this catalog as the Ninomiya Electric Wire Industry Standard. Please use it.

Conductor material JIS C1602 - 2015 ASTM E230 (formerly ANSI MC 96.1)
Types of
Insulated thermocouple wire color tolerance tolerance

thermocouples + - JIS C1610 - 2012


Color of coated

JIS C1610 -1995 Category 2 thermocouple wire


JIS C1610 -1995 Category 1 class Measurement temperature range tolerance class Measurement temperature range tolerance

-40ÿ or more and less than +375ÿ ±1.5ÿ


class 1 Sp: ±1.1ÿ or ±0.4%
nickel nickel 375ÿ or more and less than 1000ÿ ±0.004•ÿtÿ Special
- 0ÿ1260ÿ
N chromium silicon
alloy alloy
-40ÿ or more and less than +333ÿ ±2.5ÿ
pink St:
pink class 2 orange red
tea
±2.2ÿ or ±0.75%
white
333ÿ or more and less than 1200ÿ ±0.0075•ÿtÿ Standard

-40ÿ or more and less than +375ÿ ±1.5ÿ


class 1 Sp: ±1.1ÿ or ±0.4%
nickel nickel 375ÿ or more and less than 1000ÿ ±0.004•ÿtÿ Special
aluminum 0ÿ1260ÿ
K chromium
-40ÿ or more and less than +333ÿ ±2.5ÿ
alloy alloy green Red
St:
green
and white
blue
class 2 yellow red
tea
±2.2ÿ or ±0.75%
white
333ÿ or more and less than 1200ÿ ±0.0075•ÿtÿ Standard

-40ÿ or more and less than +375ÿ ±1.5ÿ


class 1 Sp: ±1.0ÿ or ±0.4%
nickel 375ÿ or more and less than 800ÿ ±0.004•ÿtÿ Special
copper nickel 0ÿ870ÿ
E chromium
±2.5ÿ
alloy -40ÿ or more and less than +333ÿ
alloy purple Red purple
St:
purple
and white
purple class 2 red
tea
±1.7ÿ or ±0.5%
white
333ÿ or more but less than 900ÿ ±0.0075•ÿtÿ Standard

-40ÿ or more and less than +375ÿ ±1.5ÿ


class 1 Sp: ±1.1ÿ or ±0.4%
375ÿ or more but less than 750ÿ ±0.004•ÿtÿ Special
copper nickel 0ÿ760ÿ
J iron
alloy -40ÿ or more and less than +333ÿ ±2.5ÿ
black Red

class 2 tea St:


black
and white
yellow
white red ±2.2ÿ or ±0.75%
Standard
and white
333ÿ or more but less than 750ÿ ±0.0075•ÿtÿ

-40ÿ or more and less than +125ÿ ±0.5ÿ


class 1 Sp: ±0.5ÿ or ±0.4%
125ÿ or more but less than 350ÿ ±0.004•ÿtÿ Special
copper nickel 0ÿ370ÿ
T copper

alloy -40ÿ or more and less than +133ÿ ±1.0ÿ blue


brown Red
tea
class 2 tea St:
white
tea
and white
red ±1.0ÿ or ±0.75%
133ÿ or more but less than 350ÿ ±0.0075•ÿtÿ Standard

* Tolerance refers to the maximum allowable value of the value obtained by subtracting the temperature of the measurement contact from the temperature converted from thermoelectromotive force using the standard thermoelectromotive force table.

* t = Measured temperature (°C) | t | is a value expressed in temperature (°C) that is unrelated to the + and - signs of the measured temperature.

*Glass insulation and ceramic insulation products are standardly identified by colored stripes.

* K-SLGB products (P.9) use polyimide paint (brown), so black stripes are the standard for identification.

*The deterioration status (life span) of thermocouple wires and compensation conductor wires varies depending on the usage environment and the size of the conductor. We recommend that you calibrate and replace it regularly.

We also accept special specification products not listed in the catalog, so please feel free to contact our sales department.
(TEL.042-753-4151) (FAX.042-753-4460) (http://www.ninomiya-ew.co.jp)

2
Machine Translated by Google

3.Shape of coated thermocouple wire

1 pair flat vinyl 1 pair flat type FEP


coated 0.65×1P Kÿ2ÿGÿJ2 (0.65×1P KÿG) coating 0.2×1P Eÿ2ÿ6FÿJ2 (0.2×1P Eÿ6F)

1 pair round vinyl 1 pair flat ceramic braided


covering 10/0.2×1P Tÿ2ÿGÿJ2=VVT (10/0.2×1P TÿG=VVT) coating 0.32×1P K-CERAC

1 pair flat type slim type glass braided 1 pair flat type silica glass
coating 0.32×1P Kÿ2ÿHmÿJ2 (0.32×1P KÿHm) braided coating 0.65×1P KÿSLGB

1 pair flat glass braided Glasses type vinyl


coating 0.32×1P Tÿ2ÿHÿJ2 (0.32×1P TÿH) coating 0.65×1P TÿG = VFF

1 pair round glass braid Ribbon type vinyl


coating 0.65×1P K-2-H-J2-SOS=GBR (0.65×1P KH-SOS=GBR) coating 0.32×12P TÿG = r

1 pair round silicone rubber UL standard certification 1 pair flat


coated 0.65×1P K - 2 - SR - J2=KKT (0.65×1P K-SR=KKT) type PFA coated AWG23 (0.65mm) x 1P KÿAStÿPFAÿASÿ [RU]

•The color of each product may differ from the actual color.

3
Machine Translated by Google

4.Usage classification/Insulator and sheath material

ÿInsulating material and operating temperature range

Item symbol Content and insulation material Operating temperature range (ÿ)

G Vinyl -20 to +90


H glass 0 to +250
Hm Glass braid, heat-resistant paint finish (slim type) 0 to +250
Hh Glass braid, heat-resistant inorganic 0 to +350
S.R. paint finish -55 to +180
SRGB Silicone rubber Silicone rubber + glass braid, heat- 0 to +180
Usage category 6F resistant paint finish -250 to +200

(Ninomiya standard) 6FGB Fluorine resin FEP Fluorine resin FEP + glass braid, heat-resistant paint finish 0 to +200
6FSR Fluorine resin FEP + silicone rubber -55 to +180
CERAC ceramic fiber braid 0 to +1000
C.F. Ceramic fiber braid (fiber sizing agent free) 0 to +1000
SLGB Silica glass (*1) braid, polyimide paint finish 0 to +600
PFA Fluororesin PFA -200 to +260
ETFE Fluororesin ETFE 90ÿ heat -100 to +150
V resistant vinyl 105ÿ heat (*2) - ~ +90
V1 resistant flame retardant vinyl -5 to +105
V2 Highly flame resistant low -10 to +90
V4 chlorine vinyl 105ÿ heat resistant soft type vinyl -30 to +105
E Polyethylene Non- -50 to +75
E2 halogen flame-retardant polyethylene Glass -30 to +75
Insulators and
G Double horizontal winding Single layer glass braiding (ÿ3)
sheath material
B Glass Single-ply (ÿ3)

K braid High-strength silicone -55 to +180


K2 rubber Flame-retardant -55 to +180
F silicone rubber -250 to +200
F2 Fluororesin FEP Fluororesin PFA -200 to +260
F3 Fluororesin ETFE -100 to +150

ÿShielding and protective braid/shape


Item symbol Contents
IS Tin-plated annealed copper wire
AIS braided inner shield Aluminum polyester tape inner shield (with drain wire)
Shielding and protective braid
OS Tin-plated annealed copper wire protection

SOS braid Stainless steel wire protection

F braid Flat type

R Round type with intervention

T Round shape without intervention

shape
P Flat type with protective braid without sheath

FF Glass-shaped flat type made by batch extrusion

r One or more pairs of fused ribbon-shaped flats

Covered thermocouple wire selection points

ÿ Thermocouple type
Due to the need for uniformity with the instruments that are connected and used, the temperature range and accuracy of the measurement

Select thermocouple type such as N, K, E, J, or T.

ÿ Selection of conductor size


Please select the conductor size such as 0.1mm, 0.2mm, 0.32mm, 0.65mm, 1.0mm, etc.
Please also refer to the table on page 16 (normal operating temperature limit and overheating operating limit temperature for thermocouple conductors).

ÿ Selection of covering material

Consider the environment in which the coated thermocouple wire will be used. For example, temperature, humidity, gas, movability, etc.
Our products can handle even harsh environments. Please also refer to the table on page 4 (insulating materials and operating temperature range).

ÿ Shielding and protective braiding


If desired, shielding and protective braiding can be provided.

Four
Machine Translated by Google

5.How to order
ÿHow to add symbols

0.65 × 1PKÿ2ÿH J 1 ÿ IS = GBR

ÿÿÿÿÿÿÿÿÿ
ÿ Conductor (see each product page)
Please select the conductor size. Stranded wire configurations can also be manufactured.

ÿ Logarithmic
1 pair (1P) means 2 cores, and thermocouples are usually used as a pair of positive and negative wires.

ÿ Thermocouple type and tolerance class ( see Table 1 below)

ÿUse classification symbol (see page 4 )


Select the material for the insulator and sheath applied to the conductor.

ÿ Identification symbol ( see Table 2 below)


Identification is done by the color of the insulator and sheath.
*Glass products, silica glass products, and ceramic fiber products are standardly identified by streaks.

ÿShield and protective braid symbols ( see page 4)


Shielding and protective braiding can be applied if necessary.

ÿÿ Insulator and sheath symbols ( see page 4)

The same material is standard for the insulator and sheath, but different materials can be combined depending on the intended use. Please select the most
suitable coating material depending on your usage conditions and application.

ÿShape _
sheath

F: Flat type
shielding
R: Round (with intervention)

T: Round (no intervention) Insulator

P: Flat type with protective braid without sheath


conductor

FF: Glasses-like flat type r:


intervention

Ribbon-like flat type

*Basically, if it is a flat type, omit ÿÿÿ after =.

table 1 Table 2

symbol Tolerance class


Item Item symbol Contents
JIS ASTM JIS ASTM

N-1 N-ASp class 1 Special J1 JIS C1610-2012 color code


N-2 N-ASt class 2 Standard identification J2 JIS C1610-1995 Category 2 color code
K-1 K-ASp class 1 Special A.S. ASTM (formerly ANSI MC96.1) color code
Type of K-2 K-ASt class 2 Standard
thermocouple wire
E-1 E-ASp class 1 Special

tolerance E-2 E-ASt class 2 Standard


class J-1 J-ASp class 1 Special
J-2 J-ASt class 2 Standard
T-1 T-ASp class 1 Special
T-2 T-ASt class 2 Standard

*The maximum temperature that each product can be used is determined by the conductor's normal use limit and overheating use limit temperature (see table on page 16) and insulation.

The temperature takes into consideration both the maximum operating temperature of the material (see page 4).

Please feel free to contact our sales department if you have any questions about how to order, coated thermocouple wires, or other special specifications of thermocouple wires.

TEL.042-753-4151 FAX.042-753 -4460 http://www.ninomiya-ew.co.jp

Five
Machine Translated by Google

RoHS compliant product

Vinyl coated thermocouple wire Maximum operating temperature: 90ÿ

A flat coated thermocouple wire with a pair of thermocouple wire conductors each insulated with vinyl and a vinyl sheath. Vinyl is the most common insulating

material and has excellent electrical properties, water resistance, and mechanical properties.

conductor

Insulator: Vinyl

Sheath: Vinyl

conductor insulator Finishing


Maximum
Approximate mass
symbol Outer diameter Outer diameter Outer diameter length of one row

mm mm mm m kg/km
0.1×1P -G-ÿ 0.1 0.5 1.0×1.5 3,000 2

0.2×1P -G-ÿ 0.2 0.6 1.2×1.8 3,000 Four

0.32×1P -G-ÿ-• 0.32 1.1 2.1×3.2 3,000 Ten

0.65×1P -G-ÿ-• 0.65 1.4 2.6×4.0 3,000 19

When ordering, please enter the symbol for the type of coated thermocouple wire and tolerance class (see Table 1 on page 5) in ÿ, and the identification symbol (see Table 2 on page 5) in ÿ.

If necessary, we also have specifications that provide shielding (to remove electrostatic induction interference) or protective braiding (to prevent damage to the coated thermocouple wire) with a thickness of 0.32

mm or more. Please place an order by placing the following symbol inside the circle.

ÿShield type IS: Tin-plated annealed copper wire braided shield ÿProtection braid

type SOS: Stainless steel wire protection braid, OS: Tin-plated annealed copper wire protection braid

[Product example]

ÿ 0.2mm K type (class 2) identification JIS classification 1 ÿ 0.2×1P Kÿ2 ÿ Gÿ J1

ÿ 0.32mm K type (class 1) identification JIS classification 2 For tin-plated annealed copper wire ÿ 0.32×1P Kÿ1 ÿ G ÿ J2 ÿ IS with
braided shielding

*We do not manufacture 0.1mm J-coated thermocouple wires. *If you

have any questions about how to add symbols, please refer to page 5 or contact our sales department. *This standard is a

symbol for specifications made of 90ÿ heat-resistant vinyl insulated and sheathed, but flame-retardant vinyl, soft type vinyl, etc. can also be manufactured. *We can

also manufacture stranded conductor specifications, round specifications, and multi-pair products with two

or more pairs. *Please refer to page 16 for various electrical resistances.

We also accept special specification products not listed in the catalog, so please feel free to contact our sales department.
(TEL.042-753-4151) (FAX.042-753-4460) (http://www.ninomiya-ew.co.jp)

6
Machine Translated by Google

RoHS compliant product

Ribbon type vinyl coated thermocouple wire Maximum operating temperature: 90ÿ

This is a ribbon-type coated thermocouple wire that uses vinyl as the insulator and has the + and - sides arranged in a flat pattern

alternately. A thermocouple wire that is compact, easy to identify, and reduces wiring mistakes.

- + - + - + - + - + - + - + - + - + - + - + - +

White red White black White Sky White green White tea White purple White orange White Ash White blue White yellow White peach white light purple

conductor

Insulator: Vinyl

Conductor finish Maximum


Approximate mass
symbol Outer diameter Outer diameter length of one row

mm mm m kg/km
0.32×12P K-G=r 0.32 1.1×26.4 100 50

0.32×12P T-G=r 0.32 1.1×26.4 100 50

RoHS compliant product

Glasses-type vinyl coated thermocouple wire (T type) Maximum operating temperature: 90ÿ

This is a glasses-type coated thermocouple wire that uses vinyl as the insulator, and the + and - sides are lined up flat and covered with vinyl insulation all at once.

Excellent workability due to batch extrusion molding.

conductor

Insulator: Vinyl

conductor Insulation finish Maximum


Approximate mass
symbol Outer diameter Outer diameter Outer diameter length of one row

mm mm mm m kg/km
0.32×1P T-G=VFF 0.32 1.2 1.2×2.4 2,000 Five

0.65×1P T-G=VFF 0.65 2.0 2.0×4.0 2,000 15

When ordering, please enter the symbol for the type of coated thermocouple wire and tolerance class (see Table 1 on page 5) in ÿ, and the identification symbol (see Table 2 on page 5) in ÿ.

*Please refer to page 16 for various electrical resistances.

We also accept special specification products not listed in the catalog, so please feel free to contact our sales department.

(TEL.042-753-4151) (FAX.042-753-4460) (http://www.ninomiya-ew.co.jp)

7
Machine Translated by Google

RoHS compliant product

glass braid coated thermocouple wire Maximum operating temperature of coating material: 250ÿ

This is a flat coated thermocouple wire in which each pair of thermocouple wire conductors is horizontally wrapped and braided insulated with glass fiber, and a glass braid is applied as a sheath. Glass is the

most common heat-resistant insulating material, but its low insulation resistance makes it unsuitable for use in humid areas.

conductor

Insulator: Glass fiber

Sheath: Glass fiber

conductor Insulator Finishing Maximum


Approximate mass
symbol Outer diameter Outer diameter Outer diameter
length of one thread

mm mm mm m kg/km
0.1×1P -H-ÿ 0.1 0.3 0.8×1.2 1,000 2

0.2×1P -H-ÿ 0.2 0.4 0.9×1.3 1,000 3

0.32×1P -H-ÿ-• 0.32 0.9 1.4×2.3 1,000 6

0.65×1P -H-ÿ-• 0.65 1.5 2.0×3.4 600 13

1.0×1P -H-ÿ-• 1.0 1.8 2.3×4.1 500 twenty five

conductor Insulator Finishing


Maximum
Approximate mass
symbol Outer diameter Outer diameter Outer diameter
length of one thread

mm mm mm m kg/km

0.32×1P -Hm-ÿ-• 0.32 0.5 1.2×1.7 1,000 Five

0.65×1P -Hm-ÿ-• 0.65 1.1 1.5×2.5 1,000 Ten

When ordering, please enter the symbol for the type of coated thermocouple wire and tolerance class (see Table 1 on page 5) in ÿ, and the identification symbol (see Table 2 on page 5) in ÿ.

If necessary, we also have specifications that provide shielding (to remove electrostatic induction interference) or protective braiding (to prevent damage to the coated thermocouple wire) with a thickness of 0.32

mm or more. Please place an order by placing the following symbol inside the circle.

ÿShield type IS: Tin-plated annealed copper wire braided shield ÿProtection braid

type SOS: Stainless steel wire protection braid, OS: Tin-plated annealed copper wire protection braid

[Product example]

ÿ 0.2mm E type (class 2) identification JIS classification 2 ÿ 0.2×1P Eÿ2 ÿ H ÿ J2

ÿ 0.32mm K type (class 1) identification JIS classification 1 For slim type ÿ 0.32×1P Kÿ1 ÿ Hmÿ J1 ÿ With SOS stainless steel wire
protection braid

*We do not manufacture 0.1mm J-coated thermocouple wires. *If you have

any questions about how to add symbols, please refer to page 5 or contact our sales department. *We can also manufacture stranded

conductor specifications, round specifications, and multi-pair products with two or more pairs. *Please refer to

page 16 for the normal operating temperature and overheating operating temperature of various electrical resistances and thermocouple conductors.

We also accept special specification products not listed in the catalog, so please feel free to contact our sales department.
(TEL.042-753-4151) (FAX.042-753-4460) (http://www.ninomiya-ew.co.jp)

8
Machine Translated by Google

RoHS compliant product

Normal temperature limit: 350ÿ


Glass braided coated thermocouple wire (K type, heat-resistant inorganic paint used) Short-term overheating usage limit temperature: 400ÿ

This is a flat coated thermocouple wire with improved heat resistance and insulation properties by wrapping a pair of thermocouple wire conductors horizontally and braiding insulation with glass fiber,

applying a glass braid as a sheath, and applying heat-resistant inorganic paint. .

conductor

Insulator: Glass fiber

Sheath: Glass fiber

conductor Insulator Finishing Maximum


Approximate mass
length of one thread
symbol Outer diameter Outer diameter Outer diameter

mm mm mm m kg/km

0.32×1P KÿHhÿ• 0.32 0.9 1.4×2.3 1,000 6

0.65×1P KÿHhÿ• 0.65 1.5 2.0×3.4 600 13

1.0×1P KÿHhÿ• 1.0 1.8 2.3×4.1 500 twenty five

If necessary, some specifications include protective braiding (to prevent damage to the coated thermocouple wire). Please place an order by placing the following symbol

inside the circle. ÿProtection braid type SOS: Stainless steel wire protection braid

Silica glass braided coated thermocouple wire (K type) RoHS compliant product

This is a flat coated thermocouple wire for high heat resistance, each pair of thermocouple wire conductors is insulated with silica glass fiber braid, silica glass braid is applied as a sheath, and polyimide

paint (brown color) is applied. It has excellent heat resistance and

electrical insulation properties at high temperatures, and maintains excellent flexibility with almost no loss in strength up to temperatures close to the normal operating limit of thermocouple conductors.

conductor

Insulator: Silica glass fiber

Sheath: Silica glass fiber

Operating temperature

Conductor Insulator Finish Maximum


Approximate mass Conductor diameter Common use temperature limit Overheating temperature limit
length of one thread
symbol Outer diameter Outer diameter Outer diameter

mm mm mm m kg/km mm ÿ ÿ

0.32×1P KÿSLGBÿ• 0.32 0.9 1.6×2.3 100 8 0.32 400 500


0.65×1P KÿSLGBÿ• 0.65 1.4 2.3×3.4 100 16 0.65 400 600
1.0×1P KÿSLGBÿ• 1.0 1.8 2.7×4.3 100 twenty five 1.0 400 600
If necessary, some specifications include protective braiding (to prevent damage to the coated thermocouple wire). Please place an order by placing the following symbol

inside the circle. ÿProtection braid type SOS: Stainless steel wire protection braid

*Please refer to page 16 for various electrical resistances.

*We can also manufacture products with tolerance class 1.

We also accept special specification products not listed in the catalog, so please feel free to contact our sales department.
(TEL.042-753-4151) (FAX.042-753-4460) (http://www.ninomiya-ew.co.jp)

9
Machine Translated by Google

Ceramic braided coated thermocouple wire (K type) RoHS compliant product

A flat coated thermocouple wire with ceramic fiber braided insulation applied to each pair of thermocouple wire conductors and a ceramic braided sheath.

conductor

Insulator: Ceramic fiber

Sheath: Ceramic fiber

conductor Insulator Finishing Maximum


Approximate mass
length of one thread
symbol Outer diameter Outer diameter Outer diameter

mm mm mm m kg/km

0.32×1P KÿCERACÿ• 0.32 1.0 1.6×2.4 1,000 7

0.65×1P KÿCERACÿ• 0.65 1.5 2.2×3.3 600 16

1.0×1P KÿCERACÿ• 1.0 1.9 2.6×4.2 500 28

0.32×1P KÿCFÿ• 0.32 1.0 1.6×2.4 100 7

0.65×1P KÿCFÿ• 0.65 1.5 2.2×3.3 100 16

1.0×1P KÿCFÿ• 1.0 1.9 2.6×4.2 100 28

If necessary, some specifications include protective braiding (to prevent damage to the coated thermocouple

wire). Please place an order by placing the following symbol inside the circle.

ÿProtection braid type SOS: Stainless steel wire protection braid

Operating temperature

Conductor diameter Common use temperature limit Overheating temperature limit

mm ÿ ÿ

0.32 400 500


0.65 650 850
1.0 750 950

•Maintains strength and flexibility even after heating.

It maintains the same level of flexibility as before heating even at temperatures above 1000ÿ, and maintains 1.5 to 2.0 times the tensile strength of conventional silica fibers even at 1200ÿ.

•Contains no acids or chlorides.

Since it does not contain acids or chlorides, it is chemically stable and does not attack metals.

•Excellent insulation resistance properties.

Maintains excellent electrical insulation properties at high temperatures.

ÿ"K-CF" is a product made from ceramic fibers without the sizing agent. The mechanical strength is weaker than K-CERAC, but the sizing agent can be used at high temperatures.

There is no generation of sizing agent gas or change in insulation properties due to thermal decomposition.

*Please refer to page 16 for various electrical resistances.

*We can also manufacture products with tolerance class 1.

We also accept special specification products not listed in the catalog, so please feel free to contact our sales department.
(TEL.042-753-4151) (FAX.042-753-4460) (http://www.ninomiya-ew.co.jp)

Ten
Machine Translated by Google

UL standard certified coated thermocouple wire RoHS compliant product

UL is an abbreviation for Underwriters Laboratories, Inc., which was established under the auspices of the Fire Insurance Association of America for the purpose of public safety inspections and to protect human

life and property from fires and other accidents. An independent non-profit organization that provides testing and certification services globally for materials, machinery, equipment, etc. Products that pass this

certification test can be affixed with the UL mark or UL label, and the safety of these products is highly evaluated in the United States. City government agencies and manufacturers are strongly demanding that

materials, machinery, equipment, etc. be UL certified as a condition for approval. Ninomiya Electric Cable Industry is the first company in Japan to obtain this UL standard for coated thermocouple wires. We also

have UL standard certified compensation conductor wires, so please use them in conjunction with UL standard certified covered thermocouple wires.

ÿ Product examples

1 pair flat PFA coated thermocouple wire 6-pair round PFA coated thermocouple wire

Cross section ÿ Cross-sectional view ÿ Cross section ÿ Cross section ÿ


conductor

conductor
Insulator: PFA

Insulator: PFA
Presser
tape
Sheath: PFA

Shielding:
Sheath: PFA
Tin-plated annealed copper wire braid (IS)

intervention

Shielding:

Tin-plated annealed copper wire braid (IS)

Symbol reference example * Cross-sectional view ÿ AWG39 (0.1mm) × 1P K-1-PFA-J1-[RU] Cross-sectional view Cross section ÿ AWG33 (0.2mm) × 6P J -ASt-PFA-AS [RU - ] = F2F2R Cross section ÿ AWG23

ÿ AWG29 (0.32mm) × 1P T-ASt-PFA-AS-IS-[RU] (0.65mm) × 6P K-ASp-PFA-AS-IS [RU - ] = F2F2R

*Since the UL standard covered thermocouple wire is a special specification, please contact our sales department for the symbol of the product you require.

ÿTypes and structures of UL standard-certified coated thermocouple wires

*Recognition Service Subject 758 File No.E173633


CategoryÿAppliance Wiring Material (AWM) Style No.21240 Rated
temperature 250ÿ/Rated voltage 150V/Flame retardant grade VW-1

•Insulated thermocouple: Use Style No. 10652 UL certified product •Number of pairs: 1 to 20
pairs •Shielding: If necessary, apply tin-
plated annealed copper wire braid •Sheath: Fluororesin PFA •Application:
Thermocouple

ÿ How to place an order When placing an order, please check the following items and contact our sales

department. •Category (AWM) and Style No.21240 *1: {Two types of standard conductors are available: AWG29 (0.32mm) and AWG 23 (0.65mm). }

•Thermocouple type and tolerance •Logarithm •Thermocouple * 2: {ASTM standard (former ANSI standard), JIS standard (IEC standard) Category 1 or Category 2}

class •Conductor size *1 wire identification* 2 •Shielding* 3 *3: Shielding is specified from 0.32mm or more.

ÿ Certified products

This is the certification of parts before they become products. It mainly applies to parts and materials that are incorporated into final products at manufacturing companies' factories.
Recognition service Recognition marks are used to display products. Our products are subject 758 AWM certified products. Our products are subject 758AWM certified products, including UL standard certified
(Recognition Service) coated thermocouple wires and UL standard certified compensating conductor wires.

Please refer to our compensation conductor catalog for UL standard certified compensation conductor wires. Alternatively, please contact our sales department.

We also accept special specification products not listed in the catalog, so please feel free to contact our sales department.

(TEL.042-753-4151) (FAX.042-753-4460) (http://www.ninomiya-ew.co.jp)

11
Machine Translated by Google

RoHS compliant product

FEP maximum operating temperature: 200ÿ

FEP coated thermocouple wire PFA Maximum operating temperature: 260ÿ

This is a flat coated thermocouple wire in which each pair of thermocouple wire conductors is insulated with fluororesin FEP (6F) and FEP is applied as a sheath. Fluororesin FEP has excellent properties in all respects including electrical properties, heat

resistance, cold resistance, oil resistance, and chemical resistance, making it an ideal insulating material. We can also manufacture coated thermocouple wires with fluororesin PFA applied to the insulator and sheath.

conductor

Insulator: FEP

Sheath: FEP

conductor Insulation finish Maximum


Approximate mass
symbol Outer diameter Outer diameter Outer diameter length of one row

mm mm mm m kg/km
0.1×1P -6F-ÿ 0.10 0.40 0.8×1.2 3,000 2

0.2×1P -6F-ÿ 0.20 0.50 0.9×1.4 3,000 3

0.32×1P -6F-ÿ-• 0.32 0.62 1.0×1.6 3,000 Five

0.65×1P -6F-ÿ-• 0.65 1.05 1.5×2.5 3,000 12

When ordering, please enter the symbol for the type of coated thermocouple wire and tolerance class (see Table 1 on page 5) in ÿ, and the identification symbol (see Table 2 on page 5) in ÿ.

*In the case of PFA insulation, the part marked 6F above is PFA. If necessary, we also have

specifications that provide shielding (to eliminate electrostatic induction interference) or protective braiding (to prevent damage to the coated thermocouple wire) with a thickness of 0.32

mm or more. Please place an order by placing the following symbol

inside the circle. ÿShield type IS: Tin-plated annealed copper wire braided shield ÿProtection

braid type SOS: Stainless steel wire protection braid, OS: Tin-plated annealed copper wire protection braid

[Product example]

ÿ 0.32mm T type (class 2) FEP insulation, identification JIS classification 2 ÿ 0.32×1P Tÿ 2 ÿ 6F ÿ J2

ÿ 0.65mm K type (ASTM special) PFA insulation, identification For ASTM ÿ 0.65×1P Kÿ ASp ÿ PFA ÿ AS ÿ IS
Tin-plated annealed copper wire with braided shielding

*We do not manufacture 0.1mm J-coated thermocouple wires. *If you


have any questions about how to add symbols, please refer to page 5 or contact our sales department. *Twisted
conductor specifications and round specifications are also available.
*Please refer to page 16 for various electrical resistances.
*We can also manufacture products with tolerance class 1.

We also accept special specification products not listed in the catalog, so please feel free to contact our sales department.

(TEL.042-753-4151) (FAX.042-753-4460) (http://www.ninomiya-ew.co.jp)

12
Machine Translated by Google

Super extra fine series RoHS compliant product

A flat coated thermocouple wire with a pair of thermocouple wire conductors each insulated with fluororesin PFA and PFA applied as a sheath.

Fluororesin PFA has excellent properties in all respects, including electrical properties, heat and cold resistance, oil and chemical resistance, and is an ideal insulating material.

conductor

Insulator: PFA

Sheath: PFA

conductor insulator Finishing Round trip conductor Conductor common Conductor Covering material Maximum
Approximate mass
symbol Outer diameter Outer diameter Outer diameter
resistance (20ÿ/standard) use limit temperature Usage
overheating temperature limit limit range length of one thread

mm mm mm ÿ/m ÿ ÿ ÿ m kg/km

Super extra-fine-005-K 0.05 0.21 0.37×0.58 494 100 200 -200 to +260 1,000 0.5

Super extra-fine-01-K 0.10 0.26 0.42×0.68 124 200 300 -200 to +260 1,000 0.7

Super extra-fine-01-T 0.10 0.26 0.42×0.68 64.6 100 150 -200 to +260 1,000 0.7

ÿFeatures

•Because it is insulated and coated with extremely thin fluororesin, it has good flexibility and an extremely thin finished outer
diameter. •It has a small heat capacity, so it has excellent thermal
response. •Fluororesin (PFA) is used for the insulation coating, so it has high heat resistance (-200ÿ to +260ÿ) and excellent chemical resistance.

*The above photo shows a tip processed as a reference example, but normally the product is sold without tip processing.
We also accept products with tip processing, mold processing, terminal processing, etc. upon request.

*Please refer to page 16 for various electrical resistances.

*We can also manufacture products with tolerance class 1.

We also accept special specification products not listed in the catalog, so please feel free to contact our sales department.
(TEL.042-753-4151) (FAX.042-753-4460) (http://www.ninomiya-ew.co.jp)

13
Machine Translated by Google

Anyone can use it with confidence

Thermocouple dedicated connector



RoHS compliant product

Ninomiya's thermocouple connector "Twinter" uses the colors of JIS and ASTM standards (formerly ANSI standards). Thermocouples, connectors, and compensation conductors can be assembled

in a uniform color, making this a highly heat-resistant connector that anyone can use with confidence. Our company, a specialized manufacturer

of compensating conductor wires and coated thermocouple wires, has developed a dedicated thermocouple connector that makes thermocouples easier to use, based on the knowledge and

technology of thermocouple temperature measurement that we have accumulated over many years.

General product

specifications

•Housing material: PPS Heat-

resistant temperature range: -50°C to +260°C

Continuous use temperature: +220°C

Flame retardant: UL94V0 Insulation

resistance: 4 x 1016 ÿ•cm Chemical resistance:

Fluororesin Excellent chemical resistance comparable to Good for general organic solvents. Oil resistance: Good against

mineral oil, grease, diesel oil, and light oil.

•Contact part

All contact parts except R are made of the same material as the thermocouple. No special correction is required. In addition, accurate
measurements are always possible even when the ambient temperature is unstable.

•Tightening torque Be

careful not to overtighten the screws. The appropriate tightening torque is set at 8.9cN•m. Additionally, the maximum tightening torque is set at 16cN•m. Do not tighten with a
tightening torque of 16 cN•m or more.

14
Machine Translated by Google

ÿStandard thermocouple connector (We also handle JIS C1610-2012 color connectors.)
Product number [JIS C1610-1995 Category 2 Color] Product number [ASTM E230 (former ANSI) color]

Metal materials used Set Set


Thermocouple symbol identification plug jack identification plug jack
(plug + jack) (plug + jack)

K cromel Armel blue NDP-T01-K NDP-P01-K NDP-J01-K yellow NDP-T01-KA NDP-P01-KA NDP-J01-KA

J iron
Copper nickel alloy yellow NDP-T01-J NDP-P01-J NDP-J01-J black NDP-T01-JA NDP-P01-JA NDP-J01-JA

T copper
Copper nickel alloy tea NDP-T01-T NDP-P01-T NDP-J01-T blue NDP-T01-TA NDP-P01-TA NDP-J01-TA

E cromel copper nickel alloy purple NDP-T01-E NDP-P01-E NDP-J01-E purple NDP-T01-EA NDP-P01-EA NDP-J01-EA

R copper Copper alloy black NDP-T01-R NDP-P01-R NDP-J01-R green NDP-T01-RA NDP-P01-RA NDP-J01-RA

Usable sheath outer diameter: 2.8mm to 6.0mm Usable conductor outer diameter: ~1.0mm

Standard option parts part number •Standard size plug & jack

cantilever cable clamp * NDC-SS 4.7ÿ


7.6
50 9

cable clamp * NDC-S


0.61

0.61
4.7ÿ

5.52
adapter NDA-S

Panel mounting bracket NDP-S rubber packing

square washer NDW-S 12.0 17.0 16.0 14.5 16.0 17.0 12.0

•Cable clamp * •Panel mounting bracket •Square washer •Adapter


Cantilevered cable
M
2.5 1.0ÿ
cable clamp M3.5 4.0 1.5
8
Ta
tap up
2.6ÿ

2.6
2.6
0.4
0.22

0.22

M2t
3
4

642
6a

ÿ3.0
.24
5

0.4
50.p

.1.4
1
6
0.3

01
9
M3.5
23.0 23.0
tap
13.0 7.5 6.0ÿ
15.0 11.0
13.5
81

81
neT

neT

5.03.1

1.0 1.0

ÿMiniature thermocouple connector (We also handle JIS C1610-2012 color connectors.)
Product number [JIS C1610-1995 Category 2 Color] Product number [ASTM E230 (former ANSI) color]

Metal materials used Set Set


Thermocouple symbol identification plug jack identification plug jack
(plug + jack) (plug + jack)

K cromel Armel blue NDP-T02-K NDP-P02-K NDP-J02-K yellow NDP-T02-KA NDP-P02-KA NDP-J02-KA

J iron
Copper nickel alloy yellow NDP-T02-J NDP-P02-J NDP-J02-J black NDP-T02-JA NDP-P02-JA NDP-J02-JA

T copper
Copper nickel alloy tea NDP-T02-T NDP-P02-T NDP-J02-T blue NDP-T02-TA NDP-P02-TA NDP-J02-TA

E cromel copper nickel alloy purple NDP-T02-E NDP-P02-E NDP-J02-E purple NDP-T02-EA NDP-P02-EA NDP-J02-EA

R copper Copper alloy black NDP-T02-R NDP-P02-R NDP-J02-R green NDP-T02-RA NDP-P02-RA NDP-J02-RA

Usable sheath outer diameter: 0.5mm to 4.0mm Usable conductor outer diameter: ~0.5mm

Miniature optional parts part number


•Miniature size plug & jack
cantilever cable clamp * NDC-MS

cable clamp * NDC-M


8.01

8.01

adapter NDA-M

Panel mounting bracket NDP-M

square washer NDW-M


8.0

•Cable clamp * •Panel mounting bracket •Square washer •Adapter


M2.5 0.5 1.0ÿ
cantilever cable cable clamp M2.5 Five
tap Tap
2.6ÿ
9.4

9.4
M1t
2

721
7a
3.61

3.61

.29
2

0.9

ÿ3.0
0.p

5
55
0.3

5.2
9
6 7
4

M2.5
17.3 17.3 tap
8.5 4.0 4.0ÿ
10.5 7.0

9.5
5.31

5.31
5.9

5.9

0.9
5 1

1.0 1.0

*For normal applications, we recommend using a cantilever clamp.

15
Machine Translated by Google

Conductor resistance value, electromotive force value, operating temperature limit

•List of round trip conductor resistance values for each size of thermocouple wire (reference value 20ÿ/standard)
(ÿ/m)
kinds
N K E J T
Conductor diameter (mm)

0.05 - 494 - - -

0.1 158 124 150 - 64.6

0.2 39.5 30.9 37.6 19.4 16.1

0.32 15.4 12.1 14.7 7.58 6.30

0.65 3.74 2.92 3.56 1.84 1.53

1.0 1.58 1.24 1.50 0.777 0.646


*It will be within ±10% of the standard value.

•Electromotive force list of thermocouple wire (JIS C1602-2015)


(ÿV)
Temperature (ÿ)
0 100 200 400 600 800 1000
kinds

N 0 2774 5913 12974 20613 28455 36256

K 0 4096 8138 16397 24905 33275 41276

E 0 6319 13421 28946 - - -

J 0 5269 10779 21848 - - -

T 0 4279 9288 - - - -

•Normal operating temperature limit and overheating operating limit temperature of thermocouple conductor

Wire diameter (mm) N K E J T


- 100 - - -
Regular use (ÿ)
0.05
- 200 - - -
Overheating (ÿ)

300 200 100 - 100


Regular use (ÿ)
0.1
400 300 150 - 150
Overheating (ÿ)

Regular use (ÿ) 400 300 200 200 100


0.2
Overheating (ÿ) 500 400 300 300 150

Regular use (ÿ) 500 400 200 200 200


0.32
Overheating (ÿ) 600 500 300 300 250

Regular use (ÿ) 850 650 450 400 200


0.65
Overheating (ÿ) 900 850 500 500 250

Regular use (ÿ) 950 750 500 450 250


1.0
Overheating (ÿ) 1000 950 550 550 300

16
Machine Translated by Google

Compensation conductor product catalog Covered thermocouple wire product catalog Heat-resistant wire product catalog

Regarding the RoHS Directive regarding restrictions on the use of specific hazardous substances All products listed in this

catalog comply with the 10 restricted substances stipulated by the RoHS Directive (2011/65/EU) and the European Commission Delegated Directive ((EU) 2015/863). There is no content above the threshold value, and it

complies with these directives.

[Usage Precautions] Please read and follow the instructions carefully to ensure safe use.

caveat Ignoring this warning and handling the product incorrectly may result in death or serious injury.
Covered thermocouple wire is not an electric wire. Do not use for general wiring. Doing so may cause electric shock, leakage, or fire. Covered thermocouple wires, which use a special metal

with a high resistance value for the conductor, can cause overcurrent when passed with the same current as general electric wires whose conductor is annealed copper wire, and there is a

risk of electrical leakage and fire. there is.

Note Ignoring this warning and handling the product incorrectly may result in injury or property damage.
Do not use in applications that are subject to repeated bending, twisting, pulling, abrasion, or vibration. This may cause wire breakage or insulation deterioration. The coated thermocouple

wires in this catalog are for

fixed wiring and cannot withstand repeated bending, twisting, pulling, abrasion, or vibration. Doing so may cause wire breakage or damage or deterioration of the insulation.

Do not use in locations exposed to water or high humidity. This may cause electrical leakage or short circuit. Braided or horizontally wound insulation made of glass fiber, silica glass fiber,

or ceramic fiber is not waterproof and may cause electrical leakage or short circuits.

Tape-wrapped insulation such as PTFE tape, polyimide tape, and mica tape are not waterproof and may cause electrical leakage or short circuits.

In order to improve quality, specifications may change without notice. note that.

Small lot Customers do not need to carry large quantities of spare parts.

Quick delivery We offer short delivery times to avoid wasting your time. Please let us know your desired delivery date.

We carefully create each step to ensure high quality . We are working on "quality stability" so that our customers can use our products with peace of mind.

17
Machine Translated by Google

Business items

ÿCompensation conductor wire ÿCoated thermocouple wire ÿHeat-resistant electric wire ÿSuper heat-resistant electric wire ÿSilicone rubber insulated electric wire ÿOther special electric wires ÿDedicated thermocouple connector

2-15-16 Fuchinobe, Chuo-ku, Sagamihara, Kanagawa 252-0206 TEL.042-753-4151 FAX.042-753-4460


http://www.ninomiya-ew.co.jp

•Due to product improvement, some information may be changed without prior notice. •The color of each product may differ from the actual color. 1712_08NA