Kitagawa Datasheet
Kitagawa Datasheet
Kitagawa Datasheet
Thermocouples are widely used in all industrial fields because they can easily provide practical performance as
temperature sensors. Ninomiya Electric Cable Industry manufactures and sells a variety of coated
thermocouple wires with high precision and excellent quality by leveraging the advanced processing technology
we have accumulated since our founding. The coated thermocouple wire has a thermocouple conductor made of
vinyl, silicone
rubber, or fluorine.
A lightweight and flexible thermocouple coated with an insulating material such as resin, glass fiber, silica glass
fiber, or ceramic fiber. Temperature can be easily measured by cutting it to the required length and electrically
convenient. We also offer special coated thermocouple wires that are used under harsh conditions, as well as
coated thermocouple wires that have passed strict inspections and quality tests and have obtained UL standard certification.
we also have ``twinter'' connectors exclusively for thermocouples and compensation conductors, so please feel
free to order.
Machine Translated by Google
INDEX
coated thermocouple wire
Glass braided coated thermocouple wire (K type, heat-resistant inorganic paint used).... 9
1.What is a thermocouple?
Create a circuit and create a temperature difference between its two contacts.
There are different types such as electrocouples, but Ninomiya Electric Wire
going.
Ninomiya Electric Wire Co., Ltd.'s coated thermocouple wires are thermocouple bare wires that comply with JIS C 1602-2015 and ASTM E230 (formerly ANSI MC 96.1).
This product is used as a conductor and is coated with insulation. In addition, since the insulator and sheath are used in a wide range of applications, we will provide compensation.
Conductive wire (JIS C 1610) is referred to, and it is included in this catalog as the Ninomiya Electric Wire Industry Standard. Please use it.
Conductor material JIS C1602 - 2015 ASTM E230 (formerly ANSI MC 96.1)
Types of
Insulated thermocouple wire color tolerance tolerance
* Tolerance refers to the maximum allowable value of the value obtained by subtracting the temperature of the measurement contact from the temperature converted from thermoelectromotive force using the standard thermoelectromotive force table.
* t = Measured temperature (°C) | t | is a value expressed in temperature (°C) that is unrelated to the + and - signs of the measured temperature.
*Glass insulation and ceramic insulation products are standardly identified by colored stripes.
* K-SLGB products (P.9) use polyimide paint (brown), so black stripes are the standard for identification.
*The deterioration status (life span) of thermocouple wires and compensation conductor wires varies depending on the usage environment and the size of the conductor. We recommend that you calibrate and replace it regularly.
We also accept special specification products not listed in the catalog, so please feel free to contact our sales department.
(TEL.042-753-4151) (FAX.042-753-4460) (http://www.ninomiya-ew.co.jp)
2
Machine Translated by Google
1 pair flat type slim type glass braided 1 pair flat type silica glass
coating 0.32×1P Kÿ2ÿHmÿJ2 (0.32×1P KÿHm) braided coating 0.65×1P KÿSLGB
•The color of each product may differ from the actual color.
3
Machine Translated by Google
Item symbol Content and insulation material Operating temperature range (ÿ)
(Ninomiya standard) 6FGB Fluorine resin FEP Fluorine resin FEP + glass braid, heat-resistant paint finish 0 to +200
6FSR Fluorine resin FEP + silicone rubber -55 to +180
CERAC ceramic fiber braid 0 to +1000
C.F. Ceramic fiber braid (fiber sizing agent free) 0 to +1000
SLGB Silica glass (*1) braid, polyimide paint finish 0 to +600
PFA Fluororesin PFA -200 to +260
ETFE Fluororesin ETFE 90ÿ heat -100 to +150
V resistant vinyl 105ÿ heat (*2) - ~ +90
V1 resistant flame retardant vinyl -5 to +105
V2 Highly flame resistant low -10 to +90
V4 chlorine vinyl 105ÿ heat resistant soft type vinyl -30 to +105
E Polyethylene Non- -50 to +75
E2 halogen flame-retardant polyethylene Glass -30 to +75
Insulators and
G Double horizontal winding Single layer glass braiding (ÿ3)
sheath material
B Glass Single-ply (ÿ3)
shape
P Flat type with protective braid without sheath
ÿ Thermocouple type
Due to the need for uniformity with the instruments that are connected and used, the temperature range and accuracy of the measurement
Consider the environment in which the coated thermocouple wire will be used. For example, temperature, humidity, gas, movability, etc.
Our products can handle even harsh environments. Please also refer to the table on page 4 (insulating materials and operating temperature range).
Four
Machine Translated by Google
5.How to order
ÿHow to add symbols
ÿÿÿÿÿÿÿÿÿ
ÿ Conductor (see each product page)
Please select the conductor size. Stranded wire configurations can also be manufactured.
ÿ Logarithmic
1 pair (1P) means 2 cores, and thermocouples are usually used as a pair of positive and negative wires.
The same material is standard for the insulator and sheath, but different materials can be combined depending on the intended use. Please select the most
suitable coating material depending on your usage conditions and application.
ÿShape _
sheath
F: Flat type
shielding
R: Round (with intervention)
table 1 Table 2
*The maximum temperature that each product can be used is determined by the conductor's normal use limit and overheating use limit temperature (see table on page 16) and insulation.
The temperature takes into consideration both the maximum operating temperature of the material (see page 4).
Please feel free to contact our sales department if you have any questions about how to order, coated thermocouple wires, or other special specifications of thermocouple wires.
Five
Machine Translated by Google
A flat coated thermocouple wire with a pair of thermocouple wire conductors each insulated with vinyl and a vinyl sheath. Vinyl is the most common insulating
material and has excellent electrical properties, water resistance, and mechanical properties.
conductor
Insulator: Vinyl
Sheath: Vinyl
mm mm mm m kg/km
0.1×1P -G-ÿ 0.1 0.5 1.0×1.5 3,000 2
When ordering, please enter the symbol for the type of coated thermocouple wire and tolerance class (see Table 1 on page 5) in ÿ, and the identification symbol (see Table 2 on page 5) in ÿ.
If necessary, we also have specifications that provide shielding (to remove electrostatic induction interference) or protective braiding (to prevent damage to the coated thermocouple wire) with a thickness of 0.32
mm or more. Please place an order by placing the following symbol inside the circle.
ÿShield type IS: Tin-plated annealed copper wire braided shield ÿProtection braid
type SOS: Stainless steel wire protection braid, OS: Tin-plated annealed copper wire protection braid
[Product example]
ÿ 0.32mm K type (class 1) identification JIS classification 2 For tin-plated annealed copper wire ÿ 0.32×1P Kÿ1 ÿ G ÿ J2 ÿ IS with
braided shielding
have any questions about how to add symbols, please refer to page 5 or contact our sales department. *This standard is a
symbol for specifications made of 90ÿ heat-resistant vinyl insulated and sheathed, but flame-retardant vinyl, soft type vinyl, etc. can also be manufactured. *We can
also manufacture stranded conductor specifications, round specifications, and multi-pair products with two
We also accept special specification products not listed in the catalog, so please feel free to contact our sales department.
(TEL.042-753-4151) (FAX.042-753-4460) (http://www.ninomiya-ew.co.jp)
6
Machine Translated by Google
Ribbon type vinyl coated thermocouple wire Maximum operating temperature: 90ÿ
This is a ribbon-type coated thermocouple wire that uses vinyl as the insulator and has the + and - sides arranged in a flat pattern
alternately. A thermocouple wire that is compact, easy to identify, and reduces wiring mistakes.
- + - + - + - + - + - + - + - + - + - + - + - +
White red White black White Sky White green White tea White purple White orange White Ash White blue White yellow White peach white light purple
conductor
Insulator: Vinyl
mm mm m kg/km
0.32×12P K-G=r 0.32 1.1×26.4 100 50
Glasses-type vinyl coated thermocouple wire (T type) Maximum operating temperature: 90ÿ
This is a glasses-type coated thermocouple wire that uses vinyl as the insulator, and the + and - sides are lined up flat and covered with vinyl insulation all at once.
conductor
Insulator: Vinyl
mm mm mm m kg/km
0.32×1P T-G=VFF 0.32 1.2 1.2×2.4 2,000 Five
When ordering, please enter the symbol for the type of coated thermocouple wire and tolerance class (see Table 1 on page 5) in ÿ, and the identification symbol (see Table 2 on page 5) in ÿ.
We also accept special specification products not listed in the catalog, so please feel free to contact our sales department.
7
Machine Translated by Google
glass braid coated thermocouple wire Maximum operating temperature of coating material: 250ÿ
This is a flat coated thermocouple wire in which each pair of thermocouple wire conductors is horizontally wrapped and braided insulated with glass fiber, and a glass braid is applied as a sheath. Glass is the
most common heat-resistant insulating material, but its low insulation resistance makes it unsuitable for use in humid areas.
conductor
mm mm mm m kg/km
0.1×1P -H-ÿ 0.1 0.3 0.8×1.2 1,000 2
mm mm mm m kg/km
When ordering, please enter the symbol for the type of coated thermocouple wire and tolerance class (see Table 1 on page 5) in ÿ, and the identification symbol (see Table 2 on page 5) in ÿ.
If necessary, we also have specifications that provide shielding (to remove electrostatic induction interference) or protective braiding (to prevent damage to the coated thermocouple wire) with a thickness of 0.32
mm or more. Please place an order by placing the following symbol inside the circle.
ÿShield type IS: Tin-plated annealed copper wire braided shield ÿProtection braid
type SOS: Stainless steel wire protection braid, OS: Tin-plated annealed copper wire protection braid
[Product example]
ÿ 0.32mm K type (class 1) identification JIS classification 1 For slim type ÿ 0.32×1P Kÿ1 ÿ Hmÿ J1 ÿ With SOS stainless steel wire
protection braid
*We do not manufacture 0.1mm J-coated thermocouple wires. *If you have
any questions about how to add symbols, please refer to page 5 or contact our sales department. *We can also manufacture stranded
conductor specifications, round specifications, and multi-pair products with two or more pairs. *Please refer to
page 16 for the normal operating temperature and overheating operating temperature of various electrical resistances and thermocouple conductors.
We also accept special specification products not listed in the catalog, so please feel free to contact our sales department.
(TEL.042-753-4151) (FAX.042-753-4460) (http://www.ninomiya-ew.co.jp)
8
Machine Translated by Google
This is a flat coated thermocouple wire with improved heat resistance and insulation properties by wrapping a pair of thermocouple wire conductors horizontally and braiding insulation with glass fiber,
conductor
mm mm mm m kg/km
If necessary, some specifications include protective braiding (to prevent damage to the coated thermocouple wire). Please place an order by placing the following symbol
inside the circle. ÿProtection braid type SOS: Stainless steel wire protection braid
Silica glass braided coated thermocouple wire (K type) RoHS compliant product
This is a flat coated thermocouple wire for high heat resistance, each pair of thermocouple wire conductors is insulated with silica glass fiber braid, silica glass braid is applied as a sheath, and polyimide
electrical insulation properties at high temperatures, and maintains excellent flexibility with almost no loss in strength up to temperatures close to the normal operating limit of thermocouple conductors.
conductor
Operating temperature
mm mm mm m kg/km mm ÿ ÿ
inside the circle. ÿProtection braid type SOS: Stainless steel wire protection braid
We also accept special specification products not listed in the catalog, so please feel free to contact our sales department.
(TEL.042-753-4151) (FAX.042-753-4460) (http://www.ninomiya-ew.co.jp)
9
Machine Translated by Google
A flat coated thermocouple wire with ceramic fiber braided insulation applied to each pair of thermocouple wire conductors and a ceramic braided sheath.
conductor
mm mm mm m kg/km
If necessary, some specifications include protective braiding (to prevent damage to the coated thermocouple
wire). Please place an order by placing the following symbol inside the circle.
Operating temperature
mm ÿ ÿ
It maintains the same level of flexibility as before heating even at temperatures above 1000ÿ, and maintains 1.5 to 2.0 times the tensile strength of conventional silica fibers even at 1200ÿ.
Since it does not contain acids or chlorides, it is chemically stable and does not attack metals.
ÿ"K-CF" is a product made from ceramic fibers without the sizing agent. The mechanical strength is weaker than K-CERAC, but the sizing agent can be used at high temperatures.
There is no generation of sizing agent gas or change in insulation properties due to thermal decomposition.
We also accept special specification products not listed in the catalog, so please feel free to contact our sales department.
(TEL.042-753-4151) (FAX.042-753-4460) (http://www.ninomiya-ew.co.jp)
Ten
Machine Translated by Google
UL is an abbreviation for Underwriters Laboratories, Inc., which was established under the auspices of the Fire Insurance Association of America for the purpose of public safety inspections and to protect human
life and property from fires and other accidents. An independent non-profit organization that provides testing and certification services globally for materials, machinery, equipment, etc. Products that pass this
certification test can be affixed with the UL mark or UL label, and the safety of these products is highly evaluated in the United States. City government agencies and manufacturers are strongly demanding that
materials, machinery, equipment, etc. be UL certified as a condition for approval. Ninomiya Electric Cable Industry is the first company in Japan to obtain this UL standard for coated thermocouple wires. We also
have UL standard certified compensation conductor wires, so please use them in conjunction with UL standard certified covered thermocouple wires.
ÿ Product examples
1 pair flat PFA coated thermocouple wire 6-pair round PFA coated thermocouple wire
conductor
Insulator: PFA
Insulator: PFA
Presser
tape
Sheath: PFA
Shielding:
Sheath: PFA
Tin-plated annealed copper wire braid (IS)
intervention
Shielding:
Symbol reference example * Cross-sectional view ÿ AWG39 (0.1mm) × 1P K-1-PFA-J1-[RU] Cross-sectional view Cross section ÿ AWG33 (0.2mm) × 6P J -ASt-PFA-AS [RU - ] = F2F2R Cross section ÿ AWG23
*Since the UL standard covered thermocouple wire is a special specification, please contact our sales department for the symbol of the product you require.
•Insulated thermocouple: Use Style No. 10652 UL certified product •Number of pairs: 1 to 20
pairs •Shielding: If necessary, apply tin-
plated annealed copper wire braid •Sheath: Fluororesin PFA •Application:
Thermocouple
ÿ How to place an order When placing an order, please check the following items and contact our sales
department. •Category (AWM) and Style No.21240 *1: {Two types of standard conductors are available: AWG29 (0.32mm) and AWG 23 (0.65mm). }
•Thermocouple type and tolerance •Logarithm •Thermocouple * 2: {ASTM standard (former ANSI standard), JIS standard (IEC standard) Category 1 or Category 2}
class •Conductor size *1 wire identification* 2 •Shielding* 3 *3: Shielding is specified from 0.32mm or more.
ÿ Certified products
This is the certification of parts before they become products. It mainly applies to parts and materials that are incorporated into final products at manufacturing companies' factories.
Recognition service Recognition marks are used to display products. Our products are subject 758 AWM certified products. Our products are subject 758AWM certified products, including UL standard certified
(Recognition Service) coated thermocouple wires and UL standard certified compensating conductor wires.
Please refer to our compensation conductor catalog for UL standard certified compensation conductor wires. Alternatively, please contact our sales department.
We also accept special specification products not listed in the catalog, so please feel free to contact our sales department.
11
Machine Translated by Google
This is a flat coated thermocouple wire in which each pair of thermocouple wire conductors is insulated with fluororesin FEP (6F) and FEP is applied as a sheath. Fluororesin FEP has excellent properties in all respects including electrical properties, heat
resistance, cold resistance, oil resistance, and chemical resistance, making it an ideal insulating material. We can also manufacture coated thermocouple wires with fluororesin PFA applied to the insulator and sheath.
conductor
Insulator: FEP
Sheath: FEP
mm mm mm m kg/km
0.1×1P -6F-ÿ 0.10 0.40 0.8×1.2 3,000 2
When ordering, please enter the symbol for the type of coated thermocouple wire and tolerance class (see Table 1 on page 5) in ÿ, and the identification symbol (see Table 2 on page 5) in ÿ.
*In the case of PFA insulation, the part marked 6F above is PFA. If necessary, we also have
specifications that provide shielding (to eliminate electrostatic induction interference) or protective braiding (to prevent damage to the coated thermocouple wire) with a thickness of 0.32
inside the circle. ÿShield type IS: Tin-plated annealed copper wire braided shield ÿProtection
braid type SOS: Stainless steel wire protection braid, OS: Tin-plated annealed copper wire protection braid
[Product example]
ÿ 0.65mm K type (ASTM special) PFA insulation, identification For ASTM ÿ 0.65×1P Kÿ ASp ÿ PFA ÿ AS ÿ IS
Tin-plated annealed copper wire with braided shielding
We also accept special specification products not listed in the catalog, so please feel free to contact our sales department.
12
Machine Translated by Google
A flat coated thermocouple wire with a pair of thermocouple wire conductors each insulated with fluororesin PFA and PFA applied as a sheath.
Fluororesin PFA has excellent properties in all respects, including electrical properties, heat and cold resistance, oil and chemical resistance, and is an ideal insulating material.
conductor
Insulator: PFA
Sheath: PFA
conductor insulator Finishing Round trip conductor Conductor common Conductor Covering material Maximum
Approximate mass
symbol Outer diameter Outer diameter Outer diameter
resistance (20ÿ/standard) use limit temperature Usage
overheating temperature limit limit range length of one thread
mm mm mm ÿ/m ÿ ÿ ÿ m kg/km
Super extra-fine-005-K 0.05 0.21 0.37×0.58 494 100 200 -200 to +260 1,000 0.5
Super extra-fine-01-K 0.10 0.26 0.42×0.68 124 200 300 -200 to +260 1,000 0.7
Super extra-fine-01-T 0.10 0.26 0.42×0.68 64.6 100 150 -200 to +260 1,000 0.7
ÿFeatures
•Because it is insulated and coated with extremely thin fluororesin, it has good flexibility and an extremely thin finished outer
diameter. •It has a small heat capacity, so it has excellent thermal
response. •Fluororesin (PFA) is used for the insulation coating, so it has high heat resistance (-200ÿ to +260ÿ) and excellent chemical resistance.
*The above photo shows a tip processed as a reference example, but normally the product is sold without tip processing.
We also accept products with tip processing, mold processing, terminal processing, etc. upon request.
We also accept special specification products not listed in the catalog, so please feel free to contact our sales department.
(TEL.042-753-4151) (FAX.042-753-4460) (http://www.ninomiya-ew.co.jp)
13
Machine Translated by Google
Ninomiya's thermocouple connector "Twinter" uses the colors of JIS and ASTM standards (formerly ANSI standards). Thermocouples, connectors, and compensation conductors can be assembled
in a uniform color, making this a highly heat-resistant connector that anyone can use with confidence. Our company, a specialized manufacturer
of compensating conductor wires and coated thermocouple wires, has developed a dedicated thermocouple connector that makes thermocouples easier to use, based on the knowledge and
technology of thermocouple temperature measurement that we have accumulated over many years.
General product
specifications
Fluororesin Excellent chemical resistance comparable to Good for general organic solvents. Oil resistance: Good against
•Contact part
All contact parts except R are made of the same material as the thermocouple. No special correction is required. In addition, accurate
measurements are always possible even when the ambient temperature is unstable.
•Tightening torque Be
careful not to overtighten the screws. The appropriate tightening torque is set at 8.9cN•m. Additionally, the maximum tightening torque is set at 16cN•m. Do not tighten with a
tightening torque of 16 cN•m or more.
14
Machine Translated by Google
ÿStandard thermocouple connector (We also handle JIS C1610-2012 color connectors.)
Product number [JIS C1610-1995 Category 2 Color] Product number [ASTM E230 (former ANSI) color]
K cromel Armel blue NDP-T01-K NDP-P01-K NDP-J01-K yellow NDP-T01-KA NDP-P01-KA NDP-J01-KA
J iron
Copper nickel alloy yellow NDP-T01-J NDP-P01-J NDP-J01-J black NDP-T01-JA NDP-P01-JA NDP-J01-JA
T copper
Copper nickel alloy tea NDP-T01-T NDP-P01-T NDP-J01-T blue NDP-T01-TA NDP-P01-TA NDP-J01-TA
E cromel copper nickel alloy purple NDP-T01-E NDP-P01-E NDP-J01-E purple NDP-T01-EA NDP-P01-EA NDP-J01-EA
R copper Copper alloy black NDP-T01-R NDP-P01-R NDP-J01-R green NDP-T01-RA NDP-P01-RA NDP-J01-RA
Usable sheath outer diameter: 2.8mm to 6.0mm Usable conductor outer diameter: ~1.0mm
Standard option parts part number •Standard size plug & jack
0.61
4.7ÿ
5.52
adapter NDA-S
square washer NDW-S 12.0 17.0 16.0 14.5 16.0 17.0 12.0
2.6
2.6
0.4
0.22
0.22
M2t
3
4
642
6a
ÿ3.0
.24
5
0.4
50.p
.1.4
1
6
0.3
01
9
M3.5
23.0 23.0
tap
13.0 7.5 6.0ÿ
15.0 11.0
13.5
81
81
neT
neT
5.03.1
1.0 1.0
ÿMiniature thermocouple connector (We also handle JIS C1610-2012 color connectors.)
Product number [JIS C1610-1995 Category 2 Color] Product number [ASTM E230 (former ANSI) color]
K cromel Armel blue NDP-T02-K NDP-P02-K NDP-J02-K yellow NDP-T02-KA NDP-P02-KA NDP-J02-KA
J iron
Copper nickel alloy yellow NDP-T02-J NDP-P02-J NDP-J02-J black NDP-T02-JA NDP-P02-JA NDP-J02-JA
T copper
Copper nickel alloy tea NDP-T02-T NDP-P02-T NDP-J02-T blue NDP-T02-TA NDP-P02-TA NDP-J02-TA
E cromel copper nickel alloy purple NDP-T02-E NDP-P02-E NDP-J02-E purple NDP-T02-EA NDP-P02-EA NDP-J02-EA
R copper Copper alloy black NDP-T02-R NDP-P02-R NDP-J02-R green NDP-T02-RA NDP-P02-RA NDP-J02-RA
Usable sheath outer diameter: 0.5mm to 4.0mm Usable conductor outer diameter: ~0.5mm
8.01
adapter NDA-M
9.4
M1t
2
721
7a
3.61
3.61
.29
2
0.9
ÿ3.0
0.p
5
55
0.3
5.2
9
6 7
4
M2.5
17.3 17.3 tap
8.5 4.0 4.0ÿ
10.5 7.0
9.5
5.31
5.31
5.9
5.9
0.9
5 1
1.0 1.0
15
Machine Translated by Google
•List of round trip conductor resistance values for each size of thermocouple wire (reference value 20ÿ/standard)
(ÿ/m)
kinds
N K E J T
Conductor diameter (mm)
0.05 - 494 - - -
T 0 4279 9288 - - - -
•Normal operating temperature limit and overheating operating limit temperature of thermocouple conductor
16
Machine Translated by Google
Compensation conductor product catalog Covered thermocouple wire product catalog Heat-resistant wire product catalog
Regarding the RoHS Directive regarding restrictions on the use of specific hazardous substances All products listed in this
catalog comply with the 10 restricted substances stipulated by the RoHS Directive (2011/65/EU) and the European Commission Delegated Directive ((EU) 2015/863). There is no content above the threshold value, and it
[Usage Precautions] Please read and follow the instructions carefully to ensure safe use.
caveat Ignoring this warning and handling the product incorrectly may result in death or serious injury.
Covered thermocouple wire is not an electric wire. Do not use for general wiring. Doing so may cause electric shock, leakage, or fire. Covered thermocouple wires, which use a special metal
with a high resistance value for the conductor, can cause overcurrent when passed with the same current as general electric wires whose conductor is annealed copper wire, and there is a
Note Ignoring this warning and handling the product incorrectly may result in injury or property damage.
Do not use in applications that are subject to repeated bending, twisting, pulling, abrasion, or vibration. This may cause wire breakage or insulation deterioration. The coated thermocouple
fixed wiring and cannot withstand repeated bending, twisting, pulling, abrasion, or vibration. Doing so may cause wire breakage or damage or deterioration of the insulation.
Do not use in locations exposed to water or high humidity. This may cause electrical leakage or short circuit. Braided or horizontally wound insulation made of glass fiber, silica glass fiber,
or ceramic fiber is not waterproof and may cause electrical leakage or short circuits.
Tape-wrapped insulation such as PTFE tape, polyimide tape, and mica tape are not waterproof and may cause electrical leakage or short circuits.
In order to improve quality, specifications may change without notice. note that.
Small lot Customers do not need to carry large quantities of spare parts.
Quick delivery We offer short delivery times to avoid wasting your time. Please let us know your desired delivery date.
We carefully create each step to ensure high quality . We are working on "quality stability" so that our customers can use our products with peace of mind.
17
Machine Translated by Google
Business items
ÿCompensation conductor wire ÿCoated thermocouple wire ÿHeat-resistant electric wire ÿSuper heat-resistant electric wire ÿSilicone rubber insulated electric wire ÿOther special electric wires ÿDedicated thermocouple connector
•Due to product improvement, some information may be changed without prior notice. •The color of each product may differ from the actual color. 1712_08NA