5000 Tds (1) 1

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

MasterSeal® HLM 5000

Liquid cold-applied elastomeric waterproofing membrane system

DESCRIPTION COMPLIANCES
MasterSeal HLM 5000 is a one-component, • ASTM C 836
moisture-curing, bitumen-modified polyurethane • National standard of Canada 37.58 - M86
elastomeric waterproofing membrane for exterior developed by CGSB
below-grade or between-slab applications.
PACKAGING
It is available in these grades:
MasterSeal HLM 5000 SL:
MasterSeal HLM 5000 SL (self-levelling/squeegee)
18.95 litre (21.999kg) pails
MasterSeal HLM 5000 R (roller)
MasterSeal HLM 5000 R:
PRODUCT HIGHLIGHTS 18.95 litre (23.814kg) pails
• Available in standard and high-build systems
• Waterproofing membrane to prevent water COVERAGE
penetration Approx. 0.6-0.7m² / litre at 1.4-1.7mm wet thickness
• Elastomeric accommodates expansion and (1.1-1.4mm dry thickness)
contraction
• Wide service-temperature range, making Coverage may vary with the application technique
MasterSeal HLM 5000 suitable for all climates used. Actual coverage rate and mil thickness
• Chemical resistance to bacterial attack, select depend on finish and porosity of the substrate.
acids, alkalis and salts
• Seamless cold-applied membrane eliminates TYPICAL PROPERTIES*
lapping, seaming and precutting
• Does not require hot-melt equipment
Property Value
Minimum recovery 90%
APPLICATIONS Swelling in water Nil
• Concrete (3 days at room temperature)
• Plywood (exterior) Service temp Min -40°C
• Exterior below grade (on masonry, concrete, Max 49°C
and incidental metal)
• Above grade (between two-course concrete and
within cavity walls)
• Parking garages and concrete tanks
• Plaza decks and malls
• Fountains and pools
• Balconies and planters
• Below-grade slabs
• Walls and culverts
• Sea walls, dams and reservoirs

COMPOSITION
MasterSeal HLM 5000 is a bitumen modified
polyurethane.
MasterSeal® HLM 5000
be sealed by caulking or prestriping (a
TEST DATA preliminary coating of MasterSeal HLM 5000
applied with a trowel or stiff-bristled brush).
MasterSeal HLM 5000 (self-levelling grade) Allow to dry overnight before applying final
Property Standard system membrane.
Shore 00 hardness, ASTM C836 85 2. When the final membrane is applied, the overall
Tensile strength ASTM D412 1.0MPa thickness over joints and cracks, at coves and
Average elongation ASTM D412 600% around penetrations should be approximately
100% modulus ASTM D412 0.6MPa 2.5mm on the standard system.
Moisture vapor permeability, dry 0.1
perms ASTM E96 STATIC JOINTS AND CRACKS
Crack bridging test: Passed 1/16 inch Joints and cracks less than 1.5mm should be
ASTM C836 No loss of bond filled by prestriping. Apply material so it both fills
cycled 10 times per 24 hours or
and overlaps the joint or crack to a width of
at -9°C cracking exhibited
Extensibility after heat aging No cracking
100mm on each side.
ASTM C836
Adhesion in peel, 5 WORKING OR EXPANSION JOINTS
(1 lb./inch min.) ASTM C836 All joints over 3mm must be sealed with a
Weight loss (20% max) 16% Master Builders Solutions urethane sealant.
ASTM C836 Any working joint less than 3mm should be
Viscosity, poise Brookfield routed to a minimum of 6mm and filled with a
MasterSeal HLM 5000 SL 125 sealant. Prevent the waterproofing membrane
MasterSeal HLM 5000 R 800 from adhering to the joint sealant, which could
Results shown are typical but are not intended as performance
criteria for on-site installed material.
cause sealant or membrane failure, by applying
*Tested in direction of greatest elongation of fabric. a coat of wax or bond breaker tape over the
cured sealant and then prestriping.
HOW TO APPLY MasterSeal HLM 5000
APPLICATION
SURFACE PREPARATION A test application is always recommended before
1. For best results, all concrete deck surfaces proceeding with entire application.
should be lightly steel trowelled to a flat, uniform NOTE: Finish coat must be applied in a pinhole-
surface. A light broom finish is acceptable. New free, continuous membrane for waterproofing
concrete must be properly water cured at least integrity.
14 days. Membrane curing compounds must be
mechanically removed.
STANDARD SYSTEM
2. For extremely porous block: Prime with a coat
1. Select the grade of MasterSeal HLM 5000 that
of MasterSeal HLM 5000 diluted up to 25% with
best meets individual job requirements. Use
a suitable Xylene thinners.
MasterSeal HLM 5000 R for roller application or
3. Remove dust, dirt and other contaminants just
MasterSeal HLM 5000 SL for squeegee
before or during application. Surfaces must be
application.
dry at the time of application.
2. For horizontal applications, empty contents of
4. Air-void pockmarks or honeycombs must be
pail and spread immediately to ensure
opened up to allow MasterSeal HLM 5000 to fill
workability. Best results are obtained by marking
the cavities completely. Air entrapment within
off approx. 11m² for 1.7mm wft or 13.5m² for
voids may cause blisters. Extreme cases may
1.4mm wft areas and evenly spreading the
require additional repair.
contents of a 18.95 litre unit with a rubber-edged
notched squeegee. Repeat the above procedure
PRESTRIPING
until the entire surface is covered.
1. Before applying the final membrane, all joints,
3. For vertical applications, apply by roller at the
cracks and openings around protrusions must
rate of 0.6-0.7m²/litre at 1.4-1.7mm wft.
MasterSeal® HLM 5000
Best results are obtained by marking off approx. application at temperatures below 4°C, consult
11m² or 13.5m² and evenly applying the contents Technical Services.
of a 18.95 litre pail. • Temperatures influence viscosity and handling
4. Verify the applied thickness with a wet mil gauge characteristics of MasterSeal HLM 5000: heat
as the work progresses. increases and cold decreases the flow. Keep
5. The integrity of the cured membrane on a MasterSeal HLM 5000 cool in hot weather and
horizontal surface may be verified by damming warm in cold weather.
the entire area and flooding with water to a • Avoid application when inclement weather is
minimum depth of 51mm and allowing the water present or imminent.
to stand for 24-48 hours. Visually inspect the • Do not apply to reinforcing bars or to wet or
bottom surface to check for any water contaminated surfaces.
penetration. If repairs are necessary, the area • Do not directly heat containers with flame,
should be drained and allowed to dry before stove, hot plate or oven.
reapplying MasterSeal HLM 5000. After • Patch all voids and deep depressions in
reapplication, the area should be tested again for substrates with appropriate patching material
membrane integrity. before applying MasterSeal HLM 5000.
• Before applying MasterSeal HLM 5000, dam all
HIGH-BUILD SYSTEM
drains and drain openings.
Concrete application: Apply approx. 1.5mm of
• Carefully work material over irregular concrete
MasterSeal HLM 5000, followed by setting
to avoid pinholes and holidays.
reinforcing fabric into the wet material. Overlap all
• Protect MasterSeal HLM 5000 coated surfaces
seams a minimum of 76mm. Additional material
from puncture with protection board until
may be required to properly embed the reinforcing
required topping or backfill is placed.
fabric where it overlaps. Allow the first coat to cure
overnight and follow with a second approx. 1.5mm • Not intended as an exposed or wearing surface.
application of MasterSeal HLM 5000. • Do not use where a solvent odour is
objectionable, e.g., near areas where food
CURING preparation or processing occur during the
Appreciable properties develop within 24-48 hours application.
at 24°C and 50% relative humidity. Protect • Specify wet or paper curing for concrete to be
MasterSeal HLM 5000 from traffic during curing. coated with MasterSeal HLM 5000; avoid using
liquid curing compounds.
DRAINAGE AND PROTECTION • In horizontal applications concrete must be
1. For protection during backfill and where slopped to drain to avoid ponding water on the
hydrostatic pressure is anticipated, use the surface of MasterSeal HLM 5000
appropriate Drain Board System for installation • When using drainage mat directly over
instructions. MasterSeal HLM 5000, a layer of 0.15mm
2. For protection during backfill only, install polyethylene sheeting should be used between
protection board as soon as possible following the MasterSeal HLM 5000 and the drainage
cure of MasterSeal HLM 5000. mat.

CLEAN UP GENERAL
• Proper application is the responsibility of the
Clean all tools and equipment immediately after
user. Field visits by BASF personnel are for the
application with a suitable Xylene thinners.
purpose of making technical recommendations
only and not for supervising or providing quality
FOR BEST PERFORMANCE control on the jobsite.
• Apply MasterSeal HLM 5000 when substrates
are dry and air temperatures are 4 to 32°C; for
MasterSeal® HLM 5000

STORAGE LIMITED WARRANTY NOTICE


Store in unopened containers in clean, dry BASF warrants this product to be free from
conditions at 4 to 27°C. manufacturing defects and to meet the technical
During storage, an easily removed skin of properties on the current Technical Data Guide, if
MasterSeal HLM 5000 may form, which does not used as directed within shelf life. Satisfactory results
affect performance of the product. depend not only on quality products but also upon
many factors beyond our control. BASF MAKES NO
SHELF LIFE OTHER WARRANTY OR GUARANTEE, EXPRESS
OR IMPLIED, INCLUDING WARRANTIES OF
MasterSeal HLM 5000 has a shelf life of 1 year for
MERCHANTABILITY OR FITNESS FOR A
pails.
PARTICULAR PURPOSE WITH RESPECT TO ITS
PRODUCTS. The sole and exclusive remedy of
VOC CONTENT Purchaser for any claim concerning this product,
- MasterSeal HLM 5000 SL: 183 g/L including but not limited to, claims alleging breach of
- MasterSeal HLM 5000 R: 180 g/L warranty, negligence, strict liability or otherwise, is
the replacement of product or refund of the
HEALTH, SAFETY AND ENVIRONMENT purchase price, at the sole option of BASF. Any
Read, understand and follow all Safety Data Sheets claims concerning this product must be received in
and product label information for this product prior to writing within one (1) year from the date of shipment
use. Use only as directed. and any claims not presented within that period are
waived by Purchaser. BASF WILL NOT BE
RESPONSIBLE FOR ANY SPECIAL, INCIDENTAL,
CONSEQUENTIAL (INCLUDING LOST PROFITS)
OR PUNITIVE DAMAGES OF ANY KIND.

Purchaser must determine the suitability of the


products for the intended use and assumes all risks
and liabilities in connection therewith.

This information and all further technical advice are


based on BASF’s present knowledge and
experience. However, BASF assumes no liability for
providing such information and advice including the
extent to which such information and advice may
relate to existing third party intellectual property
rights, especially patent rights, nor shall any legal
relationship be created by or arise from the
provision of such information and advice. BASF
reserves the right to make any changes according
to technological progress or further developments.
The Purchaser of the Product(s) must test the
product(s) for suitability for the intended application
and purpose before proceeding with a full
application of the product(s). Performance of the
product described herein should be verified by
testing and carried out by qualified experts.
MasterSeal® HLM 5000
DETAIL DRAWINGS

Dynamic Crack Detail

Vent / Drain / Pipe / Post Penetration Detail

Asphalt Pavement Topping / Expansion Joint

Split Slab with Cant Detail

Waterproofing at Bi-Level Drain


MasterSeal® HLM 5000

Expansion Joint Detail Inside Corner Detail (Static)

Static Crack / Prestripe Detail Waterproofing Foundation Walls

BASF_CC-UAE/HLM_5000_04_00/v3/02_16
The technical information and application advice given in this BASF publication are based on the present state of
STATEMENT OF our best scientific and practical knowledge. As the information herein is of a general nature, no assumption can be
RESPONSIBILITY made as to a product's suitability for a particular use or application and no warranty as to its accuracy, reliability or
completeness either expressed or implied is given other than those required by law. The user is responsible for
checking the suitability of products for their intended use.

Field service where provided does not constitute supervisory responsibility. Suggestions made by BASF either
NOTE orally or in writing may be followed, modified or rejected by the owner, engineer or contractor since they, and not
BASF, are responsible for carrying out procedures appropriate to a specific application.

BASF Construction Chemicals UAE LLC


Disclaimer: the LRQA mark relates
P.O. Box 37127, Dubai, UAE to certified management system and
Tel: +971 4 8090800, Fax: +971 4 8851002 not to the product mentioned on this
www.master-builders-solutions.basf.ae datasheet

You might also like