Scena Led 150
Scena Led 150
Scena Led 150
The information contained in this publication has been carefully prepared and
checked. However, no responsibility will be taken for any errors. All rights are
reserved and this document cannot be copied, photocopied or reproduced, in part or
completely, without prior written consent from D.T.S.
D.T.S. reserves the right to make any aesthetic, functional or design modifications to
any of its products without prior notice. D.T.S. assumes no responsibility for the use or
application of the products or circuits described herein.
Les informations contenues dans le présent manuel ont été rédigées et contrôlées
avec le plus grand soin. Nous déclinons toutefois toute responsabilité en cas
d'éventuelles inexactitudes. Tous droits réservés. Ce document ne peut être copié,
photocopié ou reproduit, dans sa totalité ou partiellement, sans le consentement
préalable de D.T.S.
D.T.S. se réserve le droit d'apporter toutes modifications et améliorations esthétiques,
fonctionnelles ou de design, sans préavis, à chacun de ses produits. D.T.S. décline
toute responsabilité sur l'utilisation ou sur l'application des produits ou des circuits
décrits.
INDEX:
1- SYMBOLS 4
2- GENERAL WARNING 4
3- GENERAL WARRANTY CONDITION 4
4- TECHNICAL FEATURES 5
5- MAIN ELECTRICAL CHARACTERISTICS 6
6- ACCESSORIES 7
7- IMPORTANT SAFETY INFORMATION 8
7.1 Fire prevention
7.2 Prevention of electric shock
7.3 Safety
8- INPUT / OUTPUT CONNECTIONS 8
9- DMX SIGNAL CONNECTION 9
9.1 DMX Addresses
9.2 Selecting the DMX address
10- FIRMWARE UPDATING 10
11- DISPLAY FUNCTIONS 11
12- SERVICE MENU 15
13- DMX PROTOCOL 16
1- SYMBOLS
2- GENERAL WARNING
Read the instruction contained in this user manual carefully, as they give important
information regarding safety during installation , use and maintenance.
The device is not for domestic use and must be installed by a qualified electrician or
experienced person.
Always disconnect the device from the mains before maintenance.
The device must always be equipped with an efficient ground connection.
The unit is guaranteed for 36 months from the date of purchase against manufacturing
material defects.
4- TECHNICAL FEATURES
OVERVIEW
PRODUCT CODES:
03.TS016.AWS SCENA LED 150 *White 3.000 °K *With Wireless on Board *PC BLACK
03.TS016.FWS SCENA LED 150 *White 3.000 °K *With Wireless on Board *FR BLACK
03.TS017.AWS SCENA LED 150 *White 4.000 °K *With Wireless on Board *PC BLACK
03.TS017.FWS SCENA LED 150 *White 4.000 °K *With Wireless on Board *FR BLACK
03.TS018.AWS SCENA LED 150 *White 5.600 °K *With Wireless on Board *PC BLACK
03.TS018.FWS SCENA LED 150 *White 5.600 °K *With Wireless on Board *FR BLACK
LED Technology
1 x White LED 3.000 °K, CRI>90, 7.000 Lumens
Also available as 4.000 °K and 5.600 °K LEDs
LED Max power: 150W
Optical group
Linear motorized zoom:
PC Version (Ø 120 mm PC lens) from min 8,2° (1.600 Lux at 5 mt)
to max 70° (185 Lux at 5 mt)
Fresnel Version (Ø 120 mm Fresnel lens) from min 12,8° (800 Lux at 5 mt)
to max 62° (250 Lux at 5 mt)
Control
4 DMX channels
LED display + 4 soft keys
Wireless ready
Connectors
Power supply: POWERCON IN & OUT Connector
DMX: 5 poles In & Out Connector
Power supply
Electronic full-range AC 90-260 V 50 / 60 Hz
Control Input:
Control Signal : DMX 512
Dimming System : Constant Current PWM
Address Range : DMX 512 channels addressable by display
6- ACCESSORIES
As standard
1 x User’s Manual
1 x POWERCON male cable connector (D.T.S. Code: 0520P014)
1 x XLR 5 pins male cable connector (D.T.S. Code: 0508B028)
1 x XLR 5 pins female cable connector (D.T.S. Code: 0508B027)
1 x Filterframe for SCENA LED 150 *Black finish (D.T.S. Code: 02M00416.46)
* “C” Clamp G60 (Max. Load. 50 Kg) *Black finish (D.T.S. Code: 0521A004)
* “C” Clamp G60 (Max. Load. 50 Kg) *Chrome finish (D.T.S. Code: 0521A004.20)
* Barndoor for SCENA LED 150 *Black finish (D.T.S. Code: 03.TBD01)
* Ø 120 mm PC lens for SCENA LED 150 (D.T.S. Code: 0506P003)
* Ø 120 mm Fresnel lens for SCENA LED 150 (D.T.S. Code: 0506P004)
* Filterframe for SCENA LED 150 *Black finish (D.T.S. Code: 02M00416.46)
DIMENSIONS
Weight Weight
5,3 Kg (PC version) 6,3 Kg (PC version)
5,1 Kg (Fresnel version) 6,1 Kg (Fresnel version)
301 mm
185 mm
250 mm 281 mm
330 mm
7.3 Safety: !
The external surface of the unit may exeed 50°C; never handle the unit until at least 5
minutes have elapsed since the unit was turned off.
Never install the unit in an enclosed area lacking sufficient air flow.
The ambient temperature should not exeed 40°C and should not be lower than -10°C.
DISPLAY PANEL
FUSE 3,15 AT
MAINS AC OUTPUT
90-260V 50/60 Hz
(MAX 14 SCENA LED 150 UNITS
@ 230V ;
MAX 7 SCENA LED 150 UNITS
@ 120V)
MAINS AC INPUT
90-260V 50/60 Hz
DMX IN DMX OUT
XLR 5 Pins Female XLR 5 Pins Male
Panel Connector Panel Connector
CONTROLLER
STANDARD
DMX 512
5 1
1=GND
2=DATA-
4 2 3=DATA+
3
DMX OUT DMX IN DMX OUT DMX IN DMX OUT DMX IN DMX OUT
If the display showing the DMX address flashes, then one of the following errors has
occurred:
- DMX signal not present
- DMX reception problem
For Installations where long distance DMX cable connections are needed, we
suggest to use a DMX terminator.
The DMX terminator is a male XLR 3-5 pins connector with a 120 ohm resistor
Between pin 2 and 3.
The DMX terminator must be plugged into the last unit (DMX out panel connector) of
the DMX line.
5 1
4 2
PLACE A 120 OHM RESISTOR BETWEEN PIN 2
3 OUT AND 3 OF A MALE XRL CONNECTOR AND PLUG IT
INTO THE DMX OUT PANEL CONNECTOR OF THE PIN 3
LAST UNIT CONNECTED TO THE DMX LINE
120 ohm
PIN 2
Projector 1 A001
Projector 2 A005 If you want to select the next projector, just add “4”
Projector 3 A009
….. A….
projector 6 A021
1) Press the UP-DOWN key until you reach the required DMX address. The numbers
on the display will start to flash (but the new DMX address hasn't yet been set).
2) Press ENTER to confirm your selection. The numbers on the display will stop
flashing and the projector is now controlled by the new DMX address.
TIPS: if you keep pushed the UP or DOWN keys, the channels are calculated more
quickly and you get a faster selection.
2) Press ENTER to confirm your selection. The numbers on the display will stop
flashing and the projector is now controlled by the new DMX address.
Warning:
This procedure require a base knowledge of Windows computer applications.
Please refer to an authorised D.T.S. service centre.
To update the software version of the SCENA LED 150 you need:
!
D.T.S. RED BOX interface (D.T.S. Code: 03.LA.008).
USB-DMX Driver for the D.T.S. RED BOX interface.
D.T.S. Firmware upgrade utility program.
(The driver and the installation procedure are available in our web site
www.dts-lighting.it)
1. Install the D.T.S. RED BOX USB-DMX driver on the PC you will use to update the
unit software.
2. Connect the D.T.S. RED BOX interface to the PC by using a USB cable.
3. Connect the D.T.S. RED BOX interface to the fixture by using a DMX cable.
4. Download the new software version into the unit by using D.T.S. Firmware upgrade
utility program.
DISPLAY FUNCTIONS
The SCENA LED 150 display panel shows all the available functions . Using these
functions, it is possible to change some of the parameters and add some functions.
Changing the D.T.S. setting can vary the functions of the unit so that it does not
respond to the DMX 512 used to control it. Carefully follow the instructions below
before carrying out any variations or selections.
NOTE: the symbol shows which key has to be pushed to obtain the desired
function.
Floor
MENU Up-Down ENTER Up-Down ENTER Up-Down ENTER
Position
REVERSE DISPLAY Suspended
ENTER
Reverses display's reading depending on Position
the mounting position (on the ground or Display
suspended). Up-Down ENTER Up-Down
Off ENTER
Display
DISPLAY STAND BY ENTER
Always on
To turn off the display (after 5 seconds)
Or leave it always on.
LED Up-Down
Default = 100 ENTER
COMPRESSION
This menu allow to select between
Linear current output or Quadratic
current output for LEDs
Default = Quadratic
SYNC
This menu allow to adjust the PWM
frequency value (Hz) in order to reduce
flickering in the process of your camera
recordings
BOOST DRIVING
This menu allow to increase the LED’s
current from Min to Max
Note:
MENU Up-Down ENTER Up-Down ENTER
External infrared remote
sensor needed (D.T.S. Code:
ENTER 03.LA.016)
INFRARED MODE
Infrared remote control.
By activating Ir Mode, it will be
possible to navigate trought the unit
functions by using the D.T.S. NOT IMPLEMENTED ON SCENA LED 150
infrared remote control
(D.T.S. Code: 0514L008)
MENU Up-Down
Wireless
ENTER Up-Down ENTER
ENTER Up-Down
Enabled
WIRELESS DMX Wireless
ENTER
Disabled
Wireless DMX enabled / disabled.
By activating WDMX MODE, it will be ENTER
UNLINK = LOG OUT
possible to control SCENA LED 150
via D.T.S. ANTENNA Wireless DMX
Transmitter (cod. 03.E1271).
Active only on SCENA LED 150 with
Wireless on board
Logging on SCENA LED 150 (WIRELESS DMX must be enabled on SCENA LED 150 unit)
To log on the SCENA LED 150 in the WIRELESS system simply press and quickly release the function button
on the transmitter.
The transmitter will start flashing rapidly red/green scanning for new free receivers / SCENA LED 150 units.
When a SCENA LED 150 logs on to the transmitter the LINK green light on transmitter starts to flash rapidly.
After approximately 10 seconds the transmitter will jump back to normal mode and continue transmitting data.
The SCENA LED 150 now try to synchronize to the transmitter.
When synchronized to the transmitter, 2 different modes are possible:
1. Antenna transmitter has detected and transmits a DMX signal, in this mode a solid green light is seen on the
transmitter and solid display is seen on SCENA LED 150.
2. No DMX signal connected, the Antenna transmitter will flash red/green; display blinking on SCENA LED
150.
To log SCENA LED 150 off from a transmitter simply select UNLINK function under
WIRELESS DMX MENU and press ENTER.
When SCENA LED 150 is logged off, the display is blinking, meaning its available for log in on a new
transmitter.
EMERGENCY ENTER
Emergency operating mode.
By setting Emergency mode, it
will be possible to select ENTER
Default = 255
Dimmer intensity level that will
then ran if DMX signal is
missing or not available.
Usefull for Emergency EXIT
ilumination on public areas.
DEFAULT SETTING
To restore default settings
LIFE TIME
This menu show the total
ENTER
unit life time and the
LED life time
SOFTWARE
Software version
LENS
PC or Fresnel ENTER
lens selection
CURRENT
From min 20 mA to max 600 mA
Default = 300 mA
ZERO OFFSET
From min 1 mm to max 50 mm
Default = 5 mm
RANGE
From min 30 mm to max 150 mm
Default = 103 mm
SPEED
Maximum speed
From min 1 mm/s to max 400 mm/s
Default = 20 mm/s
ACCELERATION
Maximum Acceleration/Deceleration
From min 1 mm/s² to max 400 mm/s²
Default = 10 mm/s²
RATIO
Transmission ratio.
From min 10 mm/turn to max 200 mm/turn
Default = 58.2 mm/turn
ENTER ENTER
RESM
To restore service and user default
settings
EXIT
ENTER Exit from service menu
4 CHANNELS MODE
1 SHUTTER / STROBE
2 DIMMER
3 ZOOM
4 RESET
NOTES
NOTES
NOTES
The information contained in this publication has been carefully prepared and
checked. However, no responsibility will be taken for any errors. All rights are reserved
and this document cannot be copied, photocopied or reproduced, in part or
completely, without prior written consent from D.T.S.
D.T.S. reserves the right to make any aesthetic, functional or design modifications to
any of its products without prior notice. D.T.S. assumes no responsibility for the use or
application of the products or circuits described herein.
MADE IN ITALY
ISO 9001:2008
D.T.S. quality system
is certified to the
ISO 9001:2008 standard
0517I197
D.T.S. Illuminazione s.r.l. – Via Fagnano Selve 10-12-14 47843
Misano Adriatico (RN) Italia
Tel.: +39 0541 611131. Fax + 39 0541 611111
[email protected] www.dts-lighting.it