SEPLOS CANBUS Protocol V1.0 www.seplos.

com

Shenzhen Seplos Technology Co., LTD


SEPLOS CANBUS Protocol V1.0 www.seplos.com

CANBUS:
Standard frame, communication rate: 500kbps, data transmission cycle: 1s.
Inverter reply every second: 0x305: 00-00-00-00-00-00-00-00

Compatible protocols:
CANBUS Protocol compatible with Pylontech V1.3 and Goodwe V1.5.

Set DIP address for parallel packs

Slave pack address:


DIP Switch
Address Remark
#1 #2 #3 #4
1 ON OFF OFF OFF PACK 1
2 OFF ON OFF OFF PACK 2
3 ON ON OFF OFF PACK 3
4 OFF OFF ON OFF PACK 4
5 ON OFF ON OFF PACK 5
6 OFF ON ON OFF PACK 6
7 ON ON ON OFF PACK 7
8 OFF OFF OFF ON PACK 8
9 ON OFF OFF ON PACK 9
10 OFF ON OFF ON PACK 10
11 ON ON OFF ON PACK 11
12 OFF OFF ON ON PACK 12
13 ON OFF ON ON PACK 13
14 OFF ON ON ON PACK 14
15 ON ON ON ON PACK 15

1
SEPLOS CANBUS Protocol V1.0 www.seplos.com

Master pack address:


Parallel DIP Switch
Remark
packs #5 #6 #7 #8
2 ON OFF OFF OFF 2 packs in parallel
3 OFF ON OFF OFF 3 packs in parallel
4 ON ON OFF OFF 4 packs in parallel
5 OFF OFF ON OFF 5 packs in parallel
6 ON OFF ON OFF 6 packs in parallel
7 OFF ON ON OFF 7 packs in parallel
8 ON ON ON OFF 8 packs in parallel
9 OFF OFF OFF ON 9 packs in parallel
10 ON OFF OFF ON 10 packs in parallel
11 OFF ON OFF ON 11 packs in parallel
12 ON ON OFF ON 12 packs in parallel
13 OFF OFF ON ON 13 packs in parallel
14 ON OFF ON ON 14 packs in parallel
15 OFF ON ON ON 15 packs in parallel

CAN ID: 0X359


Byte 0 Protection - Table 1
Byte 1 Protection - Table 2
Byte 2 Warnings - Table 3
Byte 3 Warnings - Table 4
Byte 4 Quantity of packs in parallel
Byte 5
Byte 6
Byte 7 Online address of packs in parallel - Table 5

Table 1 Protection
Bit 0
Bit 1 High voltage of battery
Bit 2 Low voltage of battery
Bit 3 Battery high temperature
Bit 4 Battery low temperature
Bit 5
Bit 6
Bit 7 Discharge over current

Table 2 Protection
Bit 0 Battery charge over current
Bit 1
Bit 2

2
SEPLOS CANBUS Protocol V1.0 www.seplos.com

Bit 3
Bit 4
Bit 5
Bit 6
Bit 7

Table 3 Warnings
Bit 0
Bit 1 Battery high voltage
Bit 2 Battery low voltage
Bit 3 Battery high temperature
Bit 4 Battery low temperature
Bit 5
Bit 6
Bit 7 Discharge over current

Table 4 Warnings
Bit 0 Charge over current of battery
Bit 1
Bit 2
Bit 3 Internal communication failure
Bit 4 Cell failure
Bit 5
Bit 6
Bit 7

Table 5 Online address of pack in parallel


Bit 0 0 means DIP 0 out-of-line, 1 means DIP 0 online
Bit 1 0 means DIP 1 out-of-line, 1 means DIP 1 online
Bit 2 0 means DIP 2 out-of-line, 1 means DIP 2 online
Bit 3 0 means DIP 3 out-of-line, 1 means DIP 3 online
Bit 4 0 means DIP 4 out-of-line, 1 means DIP 4 online
Bit 5 0 means DIP 5 out-of-line, 1 means DIP 5 online
Bit 6 0 means DIP 6 out-of-line, 1 means DIP 6 online
Bit 7 0 means DIP 7 out-of-line, 1 means DIP 7 online

CAN ID: 0X351


Byte 0
Battery charge voltage, 16 bits unsigned int, Unit: 0.1V
Byte 1
Byte 2
Charge current limit, 16 bits signed int, 2`s Byte 3Complement, Unit: 0.1A
Byte 3

3
SEPLOS CANBUS Protocol V1.0 www.seplos.com

Byte 4
Discharge current limit, 16 bits signed int, 2`s Byte 3Complement, Unit: 0.1A
Byte 5
Byte 6
Discharge voltage, 16 bits unsigned int, Unit: 0.1V
Byte 7

CAN ID: 0X355


Byte 0 SOC of single module or average value of system
Byte 1 16 bits unsigned int, Unit: 1%
Byte 2 SOH of single module or average value of system
Byte 3 16 bits unsigned int, Unit: 1%
Byte 4
Byte 5
Byte 6
Byte 7

CAN ID: 0X356


Byte 0
Battery Voltage, 16 bits signed int, 2`s Complement, Unit: 0.01V
Byte 1
Byte 2
Battery Current, 16 bits signed int, 2`s Complement, Unit: 0.1A
Byte 3
Byte 4
Battery Temperature, 16 bits signed int, 2`s Complement, Unit: 0.1℃
Byte 5
Byte 6
Byte 7

CAN ID:0x35C
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Byte 0 Table 5

Table 5
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4 Request force-charge II
Bit 5 Request force-charge I
Bit 6 Discharge-enable
Bit 7 Charge-enable

CAN ID: 0X70


Byte 0 Maximum cell temperature,
Byte 1 16bit signed int, unit :0.1degC

4
SEPLOS CANBUS Protocol V1.0 www.seplos.com

Byte 2 Minimum cell temperature,


Byte 3 16bit signed int, unit :0.1degC
Byte 4 Maximum cell voltage,
Byte 5 16bit signed int, unit :0.1degC
Byte 6 Minimum cell voltage,
Byte 7 16bit signed int, unit :0.1degC

CAN ID: 0X371


Byte 0 Maximum cell temperature ID
Byte 1 16bit signed int, unit :NA
Byte 2 Minimum cell temperature ID
Byte 3 16bit signed int, unit :NA
Byte 4 Maximum cell voltage ID
Byte 5 16bit signed int, unit :NA
Byte 6 Minimum cell voltage ID
Byte 7 16bit signed int, unit :NA

CAN ID: 0X35E


Byte 0
Manufacturer Energy ASCII
Byte 1

Note: Data 0 means low bytes. Data 1 means high bytes.