Professional Documents
Culture Documents
LED Main CID2-ATEX
LED Main CID2-ATEX
Mechanical Information
Single Units
Fixture weight: 7.14 lbs (3.24 kg)
Mounting: Threaded 1” NPT and 3/4” NPT
bottom hub for mounting
Dual Units
Fixture weight: 16.06 lbs (7.28 kg)
Mounting: Threaded 1” NPT and 3/4” NPT
bottom hub for mounting
Electrical specifications
Dimensions in inches [mm]
Volt amps: 44 VA (120V AC ) -+10%
67 VA (230V AC Units) -+15%
Input power: 14.5 W (120V AC Units)
16.0 W (230V AC Units)
Operating temp: -67ºF to +131ºF (-55ºC to +55ºC)
On / off time: 100:900 ms
Construction
Housing: Cast aluminum
Lens: Glass
Accessories (Hardware): Stainless steel
All values typical unless otherwise stated (tolerance +/- 10%)
Temperature Ratings
Class I Div. 2 models ATEX / IECEx models
Ambient Temperature Range T4A Ambient Temperature Range T4A
-67ºF to +131ºF (-55ºC to +55ºC) -67ºF to +131ºF (-55ºC to +55ºC)
14 www.dialight.com | MDTFSFSTBROCHURE_H
Hazardous Signals | LED Based Signaling SafeSite
SafeSite® L-810 LED Steady Burn Visual Signal Lights
Colored Visual Signal Lights - Class I, Div. 2 and ATEX / IECEx - V AC models
www.dialight.com | MDTFSFSTBROCHURE_H 15
SafeSite Hazardous Signals | LED Based Signaling
Mechanical Information
Fixture weight: 7.14 lbs (3.24 kg)
Mounting: Threaded 1” NPT and 3/4” NPT
bottom hub for mounting
Electrical specifications
Volt Amps: 44 VA (120V AC ) -+10%
67 VA (230V AC Units) -+15%
Input Power: 14.5 W (120V AC Units)
16.0 W (230V AC Units)
Operating Temp: -67ºF to +131ºF (-55ºC to +55ºC)
On / off time: 100:900 ms
Construction
Housing: Cast aluminum
Dimensions in inches [mm]
Lens: Glass
120V AC Models
FLS-2B01-001 Class I, Div 2, Single Unit 120V AC Blue
FLS-2G01-001 Class I, Div 2, Single Unit 120V AC Green
FLS-2R01-001 Class I, Div 2, Single Unit 120V AC Red
FLS-2Y01-001 Class I, Div 2, Single Unit 120V AC Yellow
FLS-2W01-001 Class I, Div 2, Single Unit 120V AC White
230V AC Dual Fixture Models
FLS-2B02-001 Class I, Div 2, Single Unit 230V AC Blue
FLS-2G02-001 Class I, Div 2, Single Unit 230V AC Green
FLS-2R02-001 Class I, Div 2, Single Unit 230V AC Red
FLS-2Y02-001 Class I, Div 2, Single Unit 230V AC Yellow
FLS-2W02-001 Class I, Div 2, Single Unit 230V AC White
16 www.dialight.com | MDTFSFSTBROCHURE_H
Industrial Applications | RTO Area Light SafeSite
Classes
The classes define the general nature of hazardous material in the surrounding atmosphere.
Class I Hazardous because flammable gases or vapors are present in the air in quantities sufficient to produce explosive or ignitable mixtures.
Hazardous because ignitable fibers or flying’s are present, but not likely to be in suspension in sufficient quantities to produce ignitable
Class III
mixtures. Typical wood chips, cotton, flax and nylon. Group classifications are not applied to this class.
Divisions
The division defines the probability of hazardous material being present in an ignitable concentration in the surrounding
atmosphere.
Division 2 The substance referred to by class is present only in abnormal conditions, such as a container failure or system breakdown.
Groups
The group defines the hazardous material in the surrounding atmosphere.
Group A Acetylene
Hydrogen, fuel and combustible process gases containing more than 30% hydrogen by volume or gases of equivalent hazard such as
Group B
butadiene, ethylene, oxide, propylene oxide and acrolein.
Group C Carbon monoxide, ether, hydrogen sulfide, morphline, cyclopropane, ethyl and ethylene or gases of equivalent hazard.
Gasoline, acetone, ammonia, benzene, butane, cyclopropane, ethanol, hexane, methanol, methane, vinyl chloride, natural gas, naph-
Group D
tha, propane or gases of equivalent hazard.
Combustible metal dusts, including aluminum, magnesium and their commercial alloys or other combustible dusts whose particle size,
Group E
abrasiveness and conductivity present similar hazards in connection with electrical equipment.
Carbonaceous dusts, carbon black, coal black, charcoal, coal or coke dusts that have more than 8% total entrapped volatiles or dusts
Group F
that have been sesitized by other material so they present an explosion hazard.
Group G Flour dust, grain dust, flour, starch, sugar, wood, plastic and chemicals.
Reference:
http://www.engineeringtoolbox.com/hazardous-areas-classification-d_347.html
www.dialight.com 3