Fully Auto Chemiluminescence Analyzer

www.realmindbio.com
[email protected]
Superior immunoassay
system of MCL60

Direct Chemiluminescence immunoassay (CLIA):


sensitive, specific, rapid & simple
Chemiluminescence Immunoassay (CLIA) methodology, which is applicable for various clinical
scenarios, has gained increasing attention because of its high sensitivity , specificity & wide linear
range. There are two distinct mechanisms dictating the two types of CLIA, direct and indirect.
MCL60 system applies direct CLIA with acridinium ester (AE) label.

The advantages of AE More about AE label

Qualified Result AE is a non-enzyme chemiluminescent

Low light-emitting of background and high marker in direct chemiluminescence


signal-noise ratio. analysis. It can emit light in alkaline
Less disturbance from interference factors solution containing H2O2and no cata-
during reaction. lyst required. The luminescent type of
Easy to conjugate with protein and doesn’t result AE is flash light. When luminescent
in reduction of photo yield.
triggers (NaOH & H2O2)are added, the
Fast detection light intensity reaches the peak in 0.4
Quick light-emitting, high luminous efficiency seconds.
and intensity.

Long Stability
The marker has good stability which can store
for one year under 2-8 °C.

510mm
Advantage of MCL60

Convenience fit for Clinics & Accuracy fit for Labs

Support whole blood, capillary blood, serum & plasma samples,


equipped with integrated HCT module, support on-the-fly calibration.

Easy to operate & straightforward user software, user friendly for


non-professional operators.

Fast & fully automated tests procedure with no need for manual sample
pipetting steps.

Stable & accurate assays with pg/mL sensitivity and a precision of ≤3%
CV, powered by direct CLIA technology.

510mm
Up to 144 tests per hour on a 0.52x0.64 m2 footprint, offering high
efficiency in bench space usage.

A comprehensive test menu that covers most assays a clinical lab


requests. 590mm

645mm
590mm
Learn
Learn more
more about
about MCL60
MCL60
> High throughput & small footprint
> Simple and easy operation
> Support whole blood/capillary blood/serum/plasma sample

Pipettor Incubator
Sample/reagent pipetting with high speed and ≤10μL accuracy 36 independent incubating slots
Automatic clot detection & liquid level detection Constant temperature control of 37℃±0.5℃
Inner & external washing
TEFLON coated probe to lower carry-over rate

Sample area
Up to 20 samples on board
All positions support STAT samples
Detection module
High-sensitivity and low-noise PMT
Continuous loading
Reaction vessel detection and anti-overflow function
Automatic cooling
Light-signal reading with a precision of ≤1% CV
Support different sample tubes

Reagent area
Up to 8 reagents on board
Built-in Automatic RFID reader for reagent info
Continuous loading
Automatic cooling

Washer
Strong magnetic field for fast & clean separation
Three pairs of washing needles with anti-overflow function

Reaction vessel loader


Up to 192 independent vessels on board (2x96)
Continuous loading with two plates alternating replenishment
Pushing one button and adding 96 vessels in one go
Automatically detecting empty plates
Disposable reaction vessels

HCT module
Real-time HCT calculation and online calibration for whole blood & capillary blood tests
Takes only 15μL of sample for an accurate HCT value
Works simultaneously with incubation to not slow down the sample test - time saving
User software

Main features QC & Calibration


User-friendly interface Automatic control & calibrator info

Built-in color touch screen computer reading with one swipe of RFID tag

Real-time statues monitoring of each test 2-point calibration with stability of 28


days
Reagents & consumables usage monitoring
Easy and simple operations
Comprehensive smart alarms

Pre/post defined dilution function Maintenance Guide


Automatic on-board dilution with both Smart maintenance with step by step
pre or post defined dilution ratio guide to reduce unnecessary service
calls

Detailed instruction for daily, weekly, or


Test summary monthly maintenance
Easy to read test summary for test manage-
ment (including system test, sample test,
Two-way LIS connection
calibration info, QC info, sample info, and
Two-way LIS connection by TCP/IP
reruns)
serial port and ASTM
Easy search and review test information
Test Menu

Cardiac Gastro Anemia


whole blood/serum/plasma capillary blood/whole blood/serum/plasma capillary blood/whole blood/serum/plasma

hs-cTnT G-17 *VB12


hs-cTnI PG I Fer
NT-proBNP PG II *Folate
BNP *RBC folate
MYO
CK-MB
Glycometabolism
whole blood/serum/plasma
D-Dimer Thyroid
Lp-PLA2 C-P serum/plasma

ST2 Insulin TSH


HbA1c T3
T4
Inflammation FT3
capillary blood/whole blood/serum/plasma Fertility
FT4
serum/plasma
PCT *Anti-Tg
IL-6 AMH
*Anti-TPO
IL-8 β-HCG
IL-10 FSH
TNFα LH Tumor
PRL serum/plasma
IL-1β
IL-2R PRG CEA
E2 AFP
TEST HE4
Thrombotic Disease fPSA
whole blood/serum/plasma
tPSA
Preeclampsia
TAT SCC
whole blood/serum/plasma
PIC NSE
TM PIGF CYFRA 21-1
tPAI·C sFlt-1 CA 125
D-Dimer VEGF CA 15-3
FDP CA 19-9
proGRP
Cerebral Injury
whole blood/serum/plasma
Growth & Development
capillary blood/whole blood/serum/plasma S-100

GH
IGF-I
IGFBP-3
Fer
25-OH VD

* currently under development


Fully Auto Chemiluminescence Analyzer
Key parameters
Test principle: direct chemiluminescence (acridinium ester label)
Throughput: up to 144 tests/hour
General features
24 hrs ready to use
Time to first result: 13 minutes

Operation mode STAT, batch and random

20 samples on board
Continuous loading
Sample chamber
All positions support STAT sample
Support different types of sample containers

8 reagents on board
Continuous loading
Reagent chamber
Automatic info read in by RFID barcode & reader
Refrigerated reagent area

Ready-to-use, no pretreatment required


Including calibrators and controls
50-100 tests per kit
Reagent description RFID tag with built-in master curve
2-point calibration
Calibration stability: Max 28 days

Automatic clot detection


Built-in HCT module
Other features
Liquid level detection
Constant 37°C incubation

Touch screen
Operation system
Android system, sqlite database

Interconnections Support two-way LIS

Dimensions&weight 590*645*510mm, 65kg

Rated power: 500VA


Power requirement Circuit breaker specification: F6AL250V
Power supply voltage: AC 100-240V, 50/60Hz

Performance Linear correlation: R2>0.99

Nanjing RealMind Biotech Co., Ltd.


3rd floor, Bldg. A6, Maple Science Park, Nanjing Economic and Technological Development Zone,
Nanjing, Jiangsu, 210033 CHINA
Tel: +86-15013529715
Email: [email protected]
Web: www.realmindbio.com