Electro Pneumatics Sytems
Electro Pneumatics Sytems
Chapter 2 – Electro-pneumatics
Introduction:
Electro-pneumatics systems combine electric, electronic and pneumatic technologies.
Most of the industrial applications are operated by inexpensive and reliable electro-pneumatics
components and systems.
Pneumatic systems with no electric or electronic components are usually used in places where
electricity is forbidden, such as gas factories, fuel stations etc.
Electro-pneumatics components replace mainly the pneumatics components in the control field –
from control valves, limit switches and sensors to complex control systems.
SES
34
Equipment Required:
TPS-3810/B + PNE-381H
PNE-381B – Single acting cylinder 80mm + flow control valve module
PNE-381Z – 3/2 way solenoid valve, normally closed, spring return
PNL-3810 – Electronic board including: 3 pushbuttons, 3 switches, 4 relays
12V power supply
Banana wires
A compressor
4mm flexible tubes
Discussion:
Some systems are electrically connected or operated. A pneumatic system or circuit can be operated
by pressing a pushbutton or getting an electric operating signal.
In this experiment, we will learn about some electro-pneumatic and electric components.
The first component we use is a N.C. (Normally Close) 3/2 single solenoid valve.
A R
P
Figure 2-1
This is a spring-return valve. The square with the diagonal line (next to the lever) indicates an
electric coil. Current flowing through this coil activates the valve, thus air flows from input P to
output A.
Figure 3-2 describes a circuit that includes a single acting cylinder operated by a 3/2 single solenoid
valve. The electric circuit described in figure 3-3 operates the valve.
SES
35
A+
SV+
In figure 3-3 you can see a simple ladder diagram. This ladder diagram describes the operation of
the solenoid SV1 by the pushbutton switch PB1. Pressing PB1 closes the circuit and current flows
to the coil in the SV1 valve. The current causes the valve to change its state exactly as in a similar
valve operated by air.
- +
BP SV1
The control circuit is built in the shape of branches which remind us of a ladder. This is why this
kind of electric circuit is called a ladder diagram.
The two perpendicular lines (on both sides of the diagram) indicate the voltage supply lines (the
positive and negative).
The valve's solenoid coil is called SV (Solenoid Valve). In figure 3-3, one of the coil's terminals is
connected to the positive line of the power supply and the other terminal is connected to the
negative line via a pushbutton switch.
The power supply's negative pole connects to the solenoid's coil and operates the valve when the
pushbutton is pressed.
The voltage supply lines can be replaced without affecting the system's behavior.
SES
36
Procedure:
Note:
Ensure that the valve in the air supply is closed, and that there is no pressure in the pipes.
Step 1: Install the electric component module PNL-3810 on the system's panel.
Step 2: Install the 80mm single acting cylinder module on the system's panel.
Step 4: Check the 3/2 single solenoid valve and identify the air input (P) and the air output (A).
Also identify the air release gate (usually covered with a filtering net) and the banana
sockets for connecting the voltage to the coil.
N.O.
COM
+
L1
N.C. -
Relay K1
N.O.
L2 COM
N.C.
Relay K2
N.O. S1 S2 S3
L3 COM ON/OFF Switches
N.C.
Relay K3
N.O.
L4 COM
PB1 PB2 PB3
N.C.
Relay K4 Pushbutton Switches
Step 7: Adjust the air pressure on the air supply regulator to 2 ATM.
Step 8: Connect the 12V power supply to the power inlet socket on PNL-3810.
SES
37
Step 12: Raise and lower the switch and observe the system's behavior.
Questions:
1. What operates the electric switch?
SES
38
Equipment Required:
TPS-3810/B + PNE-381H
PNE-381B – Single acting cylinder 80mm + flow control valve module
PNE-381Z – 3/2 way solenoid valve, normally closed, spring return
PNL-3810 – Electronic board including: 3 pushbuttons, 3 switches, 4 relays
12V power supply
Banana wires
A compressor
4mm flexible tubes
Discussion:
Control machines such as an electric paper cutting machine or an electric press and other machines
that perform dangerous actions sometime require safety control. To operate an electric paper cutting
machine a worker has to press two separate pushbuttons so his hands will not be near the cutting
place.
This condition for operating the machine (two pushbuttons are pressed) is called AND operation.
A+
SV+
SES
39
- +
Only if PB1 and PB2 are pressed at the same time, SV1 will be activated.
Sometimes, a certain operation can be performed from two places or more. For example, operating
a system by pressing one pushbutton or another one.
- +
PB1 SV1
PB2
SES
40
Procedure:
Note:
Ensure that the valve in the air supply is closed, and that there is no pressure in the pipes.
Step 1: Install the electric component module PNL-3810 on the system's panel.
Step 2: Install the 80mm single acting cylinder module on the system's panel.
SV1
N.O.
COM
+
L1
N.C. -
Relay K1
N.O.
L2 COM
N.C.
Relay K2
N.O. S1 S2 S3
L3 COM ON/OFF Switches
N.C.
Relay K3
N.O.
L4 COM
PB1 PB2 PB3
N.C.
Relay K4 Pushbutton Switches
Step 6: Adjust the air pressure on the air supply regulator to 2 ATM.
Step 7: Connect the 12V power supply to the power inlet socket on PNL-3810.
SES
41
SV1
N.O.
COM
+
L1
N.C. -
Relay K1
N.O.
L2 COM
N.C.
Relay K2
N.O. S1 S2 S3
L3 COM ON/OFF Switches
N.C.
Relay K3
N.O.
L4 COM
PB1 PB2 PB3
N.C.
Relay K4 Pushbutton Switches
SES
42
Questions:
1. In the following two tables describe how the two electric circuits (OR and AND) are operated:
2. If the input operational state (the manual valve) and the output operational state (the piston) is
defined a '1' and the not activated state is defined as '0', fill in the following AND function
truth table:
A B Y
0 0
0 1
1 0
1 1
3. If the input operational state (the manual valve) and the output operational state (the piston) is
defined a '1' and the not activated state is defined as '0', fill in the following OR function truth
table:
A B Y
0 0
0 1
1 0
1 1
SES
43
Equipment Required:
TPS-3810/B + PNE-381H
PNE-381B – Single acting cylinder 80mm + flow control valve module
PNE-381Z – 3/2 way solenoid valve, normally closed, spring return
PNL-3810 – Electronic board including: 3 pushbuttons, 3 switches, 4 relays
12V power supply
Banana wires
A compressor
4mm flexible tubes
Discussion:
Various consumers with different currents and voltages are needed to operate many electro-
pneumatic systems in the industry.
For example, a solenoid valve needs various voltages according to its size. A regular solenoid valve
needs a current above 2A, while a small solenoid valve need a current of 200mA-1A. This is why
we need components such as relays which can be operated with low currents and in turn can operate
a solenoid valve which is operated with high currents.
A+
SV+
Figure 2-7
SES
44
- +
PB1
R1
R1 SV1
N.O.
Figure 2-8
The relay is composed of an electromagnet (a coil with an iron core) and three contacts which
create two switches with a common contact. One switch is Normally Close (N.C.) and the second
one is Normally Open (N.O.). When current flows in the electromagnet coil, the switches change
their state.
R1
The symbol of the relay's coil is:
N.O.
The symbols of the connections are: a) Normally Open connection:
N.O.
b) Normally Close connection:
The relay's electric circuit is dismantled into two branches. The first branch includes the relay's coil
and the second branch includes the relay's switch.
The relay's coil R1 is connected (in its own circuit) to the pushbutton switch PB1.
The relay's coil R1 is used as a Normally Open (N.O.) switch which operates the solenoid valve's
coil SV1.
The connection between the two branches is because of the name R1 which appear on the relay's
coil and on the relay's switch. When the coil is operated, the switch is also operated.
SES
45
Procedure:
Note:
Ensure that the valve in the air supply is closed, and that there is no pressure in the pipes.
Step 1: Install the electric component module PNL-3810 on the system's panel.
Step 2: Install the 80mm single acting cylinder module on the system's panel.
SV1
N.O.
COM
+
L1
N.C. -
Relay K1
N.O.
L2 COM
N.C.
Relay K2
N.O. S1 S2 S3
L3 COM ON/OFF Switches
N.C.
Relay K3
N.O.
L4 COM
PB1 PB2 PB3
N.C.
Relay K4 Pushbutton Switches
Step 6: Adjust the air pressure on the air supply regulator to 2 ATM.
Step 7: Connect the 12V power supply to the power inlet socket on PNL-3810.
The K1 relay should be activated and in turn operates the valve's coil. The valve should
flow air into the piston which pops out.
SES
46
The whole process will be inverted and the piston will pop in.
SES
47
Equipment Required:
TPS-3810/B + PNE-381H
PNE-381B – Single acting cylinder 80mm + flow control valve module
PNE-381Z – 3/2 way solenoid valve, normally closed, spring return
PNL-3810 – Electronic board including: 3 pushbuttons, 3 switches, 4 relays
12V power supply
Banana wires
A compressor
4mm flexible tubes
Discussion:
We wish to operate the single acting cylinder (located in the following pneumatic system) using one
pushbutton without the need to press it all the time. The system's operation will stop by using
another pushbutton.
A+
SV+
Figure 2-9
We will use an electric circuit that operates a self-holding relay for a continuous operation of the
solenoid valve.
SES
48
- +
2 1
R1
R1
R1
SV1
R1
Figure 2-10
Operating the relay causes switch R1 (N.O. – Normally Open) to close and keep the relay operating
even after the pushbutton is released. Switch R1 also operates the solenoid valve's (SV1) coil. This
state is called "self-holding".
The function of switch 2 (N.C. – Normally Close) is to allow the relay to be released. Pressing
switch 2 stops the current from flowing into the relay, thus releases it and the piston.
There is no N.C. pushbutton in the electric circuit we have. We can implement this kind of
pushbutton using a N.O. pushbutton and a relay as described in the following electric diagram.
- +
PB1
R2
R1
R1
R1
SV1
R1
PB2
R2
Figure 2-11
R2
The symbol indicates the N.C. switch of relay R2.
Pressing pushbutton PB2 causes its N.C. switch to open and stop the current to relay R1.
SES
49
Procedure:
Note:
Ensure that the valve in the air supply is closed, and that there is no pressure in the pipes.
Step 1: Install the electric component module PNL-3810 on the system's panel.
Step 2: Install the 80mm single acting cylinder module on the system's panel.
N.O.
COM
+
L1
N.C. -
Relay K1
N.O.
L2 COM
N.C.
Relay K2
N.O. S1 S2 S3
L3 COM ON/OFF Switches
N.C.
Relay K3
N.O.
L4 COM
PB1 PB2 PB3
N.C.
Relay K4 Pushbutton Switches
Step 6: Adjust the air pressure on the air supply regulator to 2 ATM.
Step 7: Connect the 12V power supply to the power inlet socket on PNL-3810.
The K1 relay should be activated and in turn operates the valve's coil. The valve should
flow air into the piston which pops out.
SES
50
The K2 relay should be activated and in turn opens the branch of relay K1, which in
turn stops the current to the valve, which causes the piston to pop in.
Step 11: Press switches 1 and 2 simultaneously and observe the results.
Step 12: Release switches 1 and 2 simultaneously and observe the results.
Questions:
1. Why the control circuit is called a self-holding circuit?
2. Why pressing switches 1 and 2 simultaneously causes the system to not be operate?
SES
51
Equipment Required:
TPS-3810/B + PNE-381H
PNE-381A – Double acting cylinder 100mm + flow control valves module
PNE-381Y – 5/2 way double solenoid valve
PNL-3810 – Electronic board including: 3 pushbuttons, 3 switches, 4 relays
12V power supply
Banana wires
A compressor
4mm flexible tubes
Discussion:
The following system operates the double acting cylinder using a 5/2 double solenoid valve.
A+ A-
+ -
SV+ SV-
Figure 2-12
The double valve includes two non-return electric control inputs (SV+ and SV–). Moving from one
state to another is done by an electric signal given to the control inputs. Sending an electric signal to
a control input causes the valve to change its state and to not return to its previous state even if the
voltage at the input is stopped.
Each electric input has two terminals connected to the solenoid's coil.
SES
52
- +
PB1 SV+
PB2 SV-
Figure 2-13
Pressing pushbutton PB1 operates the valve which in turn operates A+ and pops the piston out.
Pressing pushbutton PB2 operates the valve which in turn operates A– and pops the piston in.
SES
53
Procedure:
Note:
Ensure that the valve in the air supply is closed, and that there is no pressure in the pipes.
Step 1: Install the electric component module PNL-3810 on the system's panel.
Step 2: Install the 100mm double acting cylinder module on the system's panel.
SV-
N.O.
COM
+
L1
SV+
N.C. -
Relay K1
N.O.
L2 COM
N.C.
Relay K2
N.O. S1 S2 S3
L3 COM ON/OFF Switches
N.C.
Relay K3
N.O.
L4 COM
PB1 PB2 PB3
N.C.
Relay K4 Pushbutton Switches
Step 6: Adjust the air pressure on the air supply regulator to 2 ATM.
Step 7: Connect the 12V power supply to the power inlet socket on PNL-3810.
The valve coil SV+ should be activated and in turn flows air to A+, thus the piston pops
out.
SES
54
The valve coil SV– should be activated and in turn flows air to A–, thus the piston pops
in.
Step 11: Press switches 1 and 2 simultaneously and observe the results.
Step 12: Release switches 1 and 2 simultaneously and observe the results.
Step 13: Press pushbutton PB1 and release it, and while the piston pops out press pushbutton
PB2.
Step 14: While the piston moves, press both pushbuttons and observe the system's behavior.
Questions:
1. What will happen if the pushbutton is pressed for a long time?
4. What will happen if one pushbutton is pressed and released, and while the piston moves the
other pushbutton is pressed?
SES
55
Equipment Required:
TPS-3810/B + PNE-381H
PNE-381A – Double acting cylinder 100mm + flow control valves module
PNE-381X – Two limit switch module
PNE-381Y – 5/2 way double solenoid valve
PNL-3810 – Electronic board including: 3 pushbuttons, 3 switches, 4 relays
12V power supply
Banana wires
A compressor
4mm flexible tubes
Discussion:
We enhance the previous system so it will operate a double action cylinder using electric limit
switches.
A+ A-
MS1 MS2
+ -
SV+ SV-
SES
56
First we operate the system using two pushbuttons (as in the previous experiment) with one
difference – we add a main switch (S1). When switch S1 is open, PB2 can cause the piston to pop
in; however, PB1 cannot pop the piston out until switch S1 is closed.
- +
S1 PB1 SV2+
PB2 SV2-
We can replace pushbuttons PB1 and PB2 with limit switches. The limit switches are pressed
alternately every time the piston reaches the end of its course. When switch S1 is closed, the system
operates automatically.
- +
S1 MS1 SV2+
MS2 SV2-
SES
57
Procedure:
Note:
Ensure that the valve in the air supply is closed, and that there is no pressure in the pipes.
Step 1: Install the electric component module PNL-3810 on the system's panel.
Step 2: Install the 100mm double acting cylinder module on the system's panel.
N.O.
COM
+
L1
SV+
N.C. -
Relay K1
N.O.
L2 COM
N.C.
Relay K2
N.O. S1 S2 S3
L3 COM ON/OFF Switches
N.C.
Relay K3
N.O.
L4 COM
PB1 PB2 PB3
N.C.
Relay K4 Pushbutton Switches
Step 6: Adjust the air pressure on the air supply regulator to 2 ATM.
Step 7: Connect the 12V power supply to the power inlet socket on PNL-3810.
SES
58
The valve coil SV+ should be activated and in turn flows air to A+, thus the piston pops
out.
The valve coil SV– should be activated and in turn flows air to A–, thus the piston pops
in.
Step 12: Press pushbutton PB1 and release it, and while the piston pops out press pushbutton
PB2.
Step 13: While the piston moves, press both pushbuttons and observe the system's behavior.
Step 17: Disconnect the wires from the pushbutton and connect them to the limit switches as
described in figure 3-16.
Step 18: How does the system behave when switch S1 is open?
Step 19: How does the system behave when switch S1 is close?
SES
59
Questions:
1. Does switch S1 affect the operation of pushbutton PB1?
3. How does the system behave when the limit switch are connected instead of the pushbuttons
according to the state of S1?
4. If we change the wires operating SV+ and SV–, how it will affect the system's operation?
5. If we exchange the wires connected to the limit switches, how it will affect the system's
operation?
SES