High-speed spectrum analyzer: 2 MHz to 2.3 GHz

u pectrum analyzers have become an For intermodulation tests on linear

S
Fast results with FFT:
Sweep time of only integral part of measuring amplifiers in base stations or adjust-
approx. 300 ms (typ.) technology in mobile radio ments to modern mobile radio phones,
for a sweep width of environments. This is due to new the spectrum analyzer option has the
100 kHz. Spectral signal transmission methods and the necessary capability.
display calculated with extremely high utilization of frequency The ease of operation, many
Fast Fourier bands. convenient features (e.g. automatic
Transformation. Wavetek has played a keyrole in tuning to level peaks, superimposition
innovations within this field and offers of two signal spectra) and the GSM
u Investigate weak a feature-rich spectrum analyzer for trigger mode for accurate adjustment
signals: the STABILOCK 4032 radio test set. of I/Q modulators.
High sensitivity for This option combines the performance The spectrum analyzer offers
monitoring frequencies features of a stand-alone analyzer with unbeatable value for money and the
even at the weakest those of professional radio measure- same versatility of use as the renowned
field strength. ment systems. STABILOCK radio test sets.

u Saving spectra:
Spectral displays can Max-Hold Function:
This display shows
be saved in the RAM or
the spectrum of a
on small memory cards GSM base channel
as a reference. This (continuous wave).
The little peak right
allows highly efficient
from the center
testing of combiner frequency for instance
networks of base is the frequency-
stations. correction channel

u High resolution:
Sweep width 1 kHz/div.
to 100 MHz/div. Level
indication dynamic
range up to 100 dB. The spectrum of this
Maximum resolution carrier is displayed as
1 dB/div. Marker lines clearly as possible.
With 100 dB display
for exact level/ range the spectrum is
frequency updated three times a
measurements. second.

Note: There is no problem upgrading your STABILOCK 4031/4032


with the spectrum analyzer. Please call us.

W

STABILOCK 4032

Technical Specifications Worldwide Sales Offices


Frequency range Level range Austria
RF –20 dBm to +50 dBm
Wavetek Ges.m.b.H.
Standard: 2 MHz to 999 MHz
Pharos Haus
With RF frequency extension (optional) 1): RF DIRECT –40 dBm to +20 dBm Nordbahnstrasse 36/TOP 1.4
1000 MHz to 2300 MHz 2) Increment 10 dB 1020 Vienna, Austria
1790 MHz to 2020 MHz 3) Tel: (43) 1-214-5110
Fax: (43) 1-214-5109
Max. dynamic measuring range
Accuracy for measuring errors < 3 dB China
< 2% of sweep width Sweep width 10 kHz 75 dB (typ. 80 dB) 6)
Wavetek Corporation
Room 2701, CITIC Building
Sweep width / evaluation bandwidth / Sweep width < 200 kHz 65 dB (typ. 70 dB) 6) No. 19 Jianguomenwai Dajie
Sweep width < 10 MHz 60 dB (typ. 65 dB) Beijing 100004, P.R. China
sweep time
Tel: (86) 10-6592-8044
Sweep width evaluation sweep std 2) 3) Sweep width < 50 MHz 55 dB (typ. 60 dB) Fax: (86) 10-6500-8199
bandwidth time
Image frequency interference 4) France
FFT 10 kHz 100 Hz < 0.5 s x x x Wavetek S.A.
FFT 20 kHz 200 Hz < 0.5 s x x x No image frequency interference at all non-FFT 12 Boulevard des Iles
FFT 50 kHz 500 Hz < 0.4 s x x x spans Immeuble Seine St-Germain, Bât. B
92441 Issy-les-Moulineaux Cédex, France
FFT 100 kHz 1 kHz < 0.3 s x x x
Tel: (33) 1-4190-6666
FFT 200 kHz 3 kHz < 0.3 s x x x Fax: (33) 1-4190-6650
1) Compliance with guaranteed technical specifications up
200 kHz 3 kHz < 0.6 s x x
500 kHz 3 kHz < 0.6 s x x to 2.0 GHz. The options “RF frequency extension” and Germany
“2nd RF generator” cannot be operated at the same time. Wavetek GmbH
1 MHz 10 kHz < 0.5 s x x
2) with RF frequency extension (optional) Gutenbergstrasse 2-4
2 MHz 10 kHz < 0.5 s x x 85737 Ismaning, Germany
3) for STABILOCK 4032 with serial number ≥ 1688 000
5 MHz 30 kHz < 0.5 s x x Tel: (49) 89-99641-0
4) 80 dB for sweep widths at non-FFT spans
10 MHz 30 kHz < 0.5 s x x Fax: (49) 89-99641-160
5) for sweep width > 200 kHz
20 MHz 100 kHz < 0.8 s x x
6)
Hong Kong
50 MHz 400 kHz < 0.8 s x x The max. dynamic measuring range above 1 GHz
Wavetek Hong Kong Ltd.
is 6 dB lower.
100 MHz 400 kHz < 0.8 s x x 3A, HKPC Building
200 MHz 400 kHz < 1.0 s x x 78 Tat Chee Avenue
500 MHz 400 kHz < 1.0 s x Kowloon, Hong Kong
125 to 1000 MHz 400 k’Hz < 1.5 s x
Ordering information Tel: (852) 2788-6221
Fax: (852) 2788-6220
STABILOCK 4032 ....................................... 108 802
Display resolution Japan
Spectrum analyzer 4031 ............................. 248 290 Yokogawa Wavetek Corporation
1 dB/div. (log)
Spectrum analyzer 4032 ............................. 248 291 4F, Promity Fuchinobe Building
10 dB/div. (log) 9-15, Kanumadai 1-chome
RF frequency extension 2.3 GHz ................. 248 295 Sagamihara-shi,
Display range 3) Kanagawa-ken 229-0033, Japan
100 dB (FFT spans) Tel: (81) 427-57-3444
Please consult your Wavetek branch for STABILOCK Fax: (81) 427-57-5722
80 dB for sweep widths at non-FFT spans 4031 units with serial numbers up to 588000.
The Americas
Wavetek Corporation
5808 Churchman Bypass
Indianapolis, IN 46203, USA
Tel: (1) 317-788-9351
Your nearest representative: Fax: (1) 317-782-4607
Singapore
Wavetek Asia-Pacific Pte. Ltd.
51 Goldhill Plaza #14-04/05
Singapore 308900
Tel: (65) 356-2522
Fax: (65) 356-2553
United Kingdom
Wavetek Ltd.
Hurricane Way
Norwich, Norfolk NR6 6JB, U.K.
Tel: (44) 1603-256-700
Fax: (44) 1603-256-688
STABILOCK is a registred trademark of Wavetek GmbH. Wavetek is a registered trademark of Wavetek Corporation.
Subject to alterations. 295 092 / 4032 Analyzer– 06.98 (E)  Wavetek GmbH 1998 Internet: www.wavetek.com

You might also like