Architecture
PowerStore utilizes Intel® Xeon® Scalable processors, plus a flexible all-NVMe design featuring dual-ported Intel®
Optane™ SSDs and NVMe-over-fabric networking (both FC and TCP), to deliver end-to-end low latency performance for
any workload. Always-on data reduction, intelligent automation, active resource balancing, predictive analytics and non-
disruptive software and hardware upgrades keep your storage environment continuously optimized, up-to-date and easy
to manage, even as your needs evolve over time.
Expansion enclosures 2U enclosures with twenty-four (24) 2.5” NVMe drives slots, up to three per appliance
Power supplies Two redundant power supplies (PS) per base and per expansion enclosure.
Data resiliency Dynamic Resiliency Engine (DRE), protects against multiple simultaneous drive failures
Max mezzanine cards2 2 2 2 2 2
3
Max IO modules 4 4 4 4 4
Backend expansion 4x25GbE ports 4x100GbE QSFP ports
5
Max capacity per cluster 24.64 PBe 23.60 PBe 23.60 PBe 23.60 PBe 23.60 PBe
Note clusters can include any combination of appliance models. All models scale to >23 PBe max capacity per cluster.
1 Cluster max. initiators only apply to PowerStore 1200 thru 9200 models
Connectivity options
Type Description Details
Mezzanine card / IO Module * Two-Port 10 Gb/s Optical Module Two port 10GbE IP/iSCSI module. Uses SFP+ optical connection
(Block) or active/passive twinax copper connection to Ethernet switch
Mezzanine card / IO Module ** Four-Port 10GBASE-T Module (File & Four port 10GBASE-T Ethernet IP/iSCSI module with copper
Block) connection to Ethernet switch
Mezzanine card / IO Module *** Four port IP/iSCSI module supporting 25GbE or 10GbE. Uses
Four-Port 25 Gb/s Optical Module (File
SFP+ optical connection or twinax copper connection (active/
& Block)
passive for 10GbE, passive for 25GbE) to Ethernet switch
IO Module Four port FC module with choice of 16Gb/s or 32Gb/s
Four-Port 32 Gb/s Fibre Channel
connectivity. Uses multimode optical SFP and OM2/OM3/OM4
Module (Block only)
cabling to connect directly to host HBA or FC switch
IO Module **** Four port 10GBASE-T Ethernet IP/iSCSI module with copper
Four-Port 10GBASE-T Module
connection to Ethernet switch
IO Module **** Four port IP/iSCSI module supporting 25GbE or 10GbE. Uses
Four-Port 25 Gb/s Optical Module SFP+ optical connection or twinax copper connection (active/
passive for 10GbE, passive for 25GbE) to Ethernet switch
IO Module ** Two port IP/iSCSI module with QSFP optical or active/passive
Two-Port 100 Gb/s Optical Module
copper connection to Ethernet switch
* Only available for PowerStore 500T
** Not available for PowerStore 500T
*** Ports 2 and 3 on the 4-Port Mezzanine card on 500T are reserved for backend connectivity
Supported media
Raw base-10 Raw base-2 Expansion
Drive Type Interface Capacity * Capacity ** Base Enclosure Enclosure
NVMe TLC SSD PCIe 1.92 TB 1.7466 TiB ✓ ✓
NVMe TLC SSD PCIe 3.84 TB 3.4931 TiB ✓ ✓
All drives are SED. FIPS validated drives are available as an option. Consult a Dell or Partner Sales Rep for additional guidance
IPv6 USGv6-R1 certification
TLS 1.2 support by default, TLS 1.1 and older are disabled by default. TLS 1.1 can be optionally enabled.
*PowerStoreOS 3.5 has been STIG-hardened to meet the security requirements of the US Department of Defense.
MyService360
Services & Support Technologies
Software
Management Software:
• PowerStore Manager
• Infrastructure Observability (cloud-based storage analytics with ProSupport
• Thin Provisioning
• Dynamic Resiliency Engine (DRE) – Single & Dual parity
• Data Reduction: Zero Detect/Deduplication/Compression
• Proactive Assist: Configure remote support, online chat, open a service request, etc.
• Quality of Service (Block and vVols)
• Capacity Accounting
Protocols: PowerStore T/Q Models
• Block
• vVols
• File
All Inclusive Base Software
Local Protection:
• SED Based Encryption with self-managed and external key management
• Local Point-In-Time Copies (Snapshots and Thin Clones)
• Immutable & Secure Snapshots
• AppSync Basic
• File Level Retention (FLR)
• Dell Common Event Enabler; AntiVirus Agent (CEPA)
Remote Protection:
• Native Synchronous/Asynchronous Block Replication
• Native Asynchronous vVol Replication
• Native Metro Volume Synchronous Block Replication (VMware, Windows, Linux)
• Native Synchronous/Asynchronous File Replication
• Native PowerProtect DD integration - manage local or multicloud backups
directly from PowerStore
Migration:
• Native Block migration from Unity, Unity XT, VNX, SC Series, PS Series, FC/iSCSI source arrays
• Native File migration for VNX, Unity and via included DataDobi software for third party file
sources
AppSync Advanced
Connectrix SAN
Data Protection Suite: Backup, Archive and Collaboration Software
Dell RP4VM
Optional Solutions
PowerPath Migration Enabler
PowerPath Multipathing
PowerStore metro node (block synchronous metro Active/Active, zero RPO/RTO)
VPLEX
Note: For more details on software licensing, please contact your sales representative
• Dell Virtual Storage Integrator (VSI) for VMware vSphere™: For provisioning, management, and cloning
• OpenStack Cinder Driver: For provisioning and managing block volumes within an OpenStack environment
• VMware Site Recovery Manager (SRM) Integration: Managing failover and failback making disaster recovery rapid and reliable
• Virtualization API Integration: VMware: VAAI and VASA.
• vRO Plugin for PowerStore
• Container Storage Interface (CSI) Plugin for PowerStore
• Ansible Module for PowerStore
• Terraform Provider
Electrical specifications
Power figures represent product configurations in typical operating conditions of 26°C and worst-case, maximums
operating in extreme temperature environments of 40°C.
21x2.5” 21x2.5”
21x2.5” drives,
drives, drives, 21x2.5” drives,
25x2.5” drives, 2xNVRAM
2xNVRAM 4xNVRAM 4xNVRAM modules
four IO modules
modules modules four IO modules
modules four IO modules
four IO modules four IO modules
Power
100-240 VAC ± 10%, single phase, 47 to 63 Hz (500T)
AC Line Voltage
200-240 VAC ± 10%, single phase, 47 to 63 Hz (1200-9200)
AC Line Current
Typical operating 7 A max at 100V 5.4 A max 5.8 A max
4.7 A max at 200V 7.1 A max at 200V 8.1 A max at 200V
temperature of 26°C 3.5 A max at 200V at 200V at 200V
Maximum operating 10 A max at 100V 7.1 A max 7.7 A max
6.5 A max at 200V 8.8 A max at 200V 9.8 A max at 200V
temperature of 40°C 5 A max at 200V at 200V at 200V
Power Consumption
683.5 W (697.4 VA) 921.8 W (940.6 VA) 1056.4 W 1140.9 W 1391.2 W (1419.6 1597 W (1629.6VA)
Typical operating max at 200V-240V max at 200V-240V (1078 VA) max (1164.2 VA) VA) max at 200V- max at 200V-240V (+/-
temperature of 26°C (+/- 10%) at 200V-240V max at 200V- 240V (+/- 10%) 10%)
(+/- 10%) 240V (+/- 10%)
984 W (1004.1 VA) 1271.3 W 1393.6 W 1505.1 W 1734.4 W (1769.8 1919.4 W (1958.6 VA)
Maximum operating max at 200V-240V (1297.2 VA) (1422.0 VA) (1535.8 VA) VA) max at 200V- max at 200V-240V
temperature of 40°C max at 200V- max at 200V- max at 200V- 240V (+/- 10%) (+/- 10%)
240V (+/- 10%) 240V (+/- 10%) 240V (+/- 10%)
Heat Dissipation
2.46 x 106 J/hr 3.32 x 106 J/hr, 3.80 x 106 J/hr, 4.11 x 106 J/hr, 5.01 x 106 J/hr, 5.75 x 106 J/hr,
Typical operating (2,332 Btu/hr) max (3,145 Btu/hr) max (3,605 Btu/hr) (3,893 Btu/hr) (4,747 (5,449 Btu/hr) max
temperature of 26°C 200VAC 200VAC max 200VAC max 200VAC Btu/hr) max 200VAC
200VAC
3.54 x 106 J/hr 4.58 x 106 J/hr, 5.02 x 106 J/hr, 5.42 x 106 J/hr, 6.24 x 106 J/hr, 6.91 x 106 J/hr,
Maximum operating (3,358 Btu/hr) max (4,338 Btu/hr) max (4,755 Btu/hr) (5,136 Btu/hr) (5,918 Btu/hr) max (6,549 Btu/hr) max
temperature of 40°C 200VAC 200VAC max 200VAC max 200VAC 200VAC 200VAC
Note: Power consumption values for enclosures are based on fully populated enclosures (power supplies, drives and I/O modules).
*PowerStore models 500T, 1200T, 3200T and 5200T only are ENERGY STAR Certified
Weight and Dimensions
Weight kgs/lbs Empty: Empty Empty Empty Empty
30.38/66.97 35.80/79 35.80/79 35.80/79 35.80/79
Full: 37.4/82.4 Full 41.7/92 Full 41.7/92 Full 41.7/92 Full 41.7/92
Vertical size 2 NEMA units 2 NEMA units 2 NEMA units 2 NEMA units 2 NEMA units
Height cm/inches 8.72/3.43 8.72/3.43 8.72/3.43 8.72/3.43 8.72/3.43
Width cm/inches 44.72/17.61 44.72/17.61 44.72/17.61 44.72/17.61 44.72/17.61
Depth cm/inches 79.55/31.32 79.55/31.32 79.55/31.32 79.55/31.32 79.55/31.32
* PowerStore 500T supports running native low line power (100-120VAC +/-10)
Maximum operating temperature of 40°C 2.29 x 106 J/hr. (2,170 Btu/hr.) max 200VAC
In-rush Current 82A max for 1/2 Line cycle per line cord at 200 VAC
Startup Surge Current 100 Apk Max for up to 125uSec
AC Protection 15 A fuse on each power supply, single line
AC Inlet Type IEC320-C14 appliance coupler, per power zone
Ride-through Time 10 ms minimum
Current Sharing ± 5 percent of full load, between power supplies
Cabinets
Standard 42U Cabinet
Power Configuration One, two, three, four, five, six power domains, each redundant
Power Inlet Count Two, four, six, eight, ten, or twelve (two per domain)
Height – 78.4 in (199.1 cm); Width - 23.6 in (60.0 cm); Depth - 39.3 in (99.8 cm); Weight Empty
42U Cabinet Dimensions
– 387 lb (176 kg)
Operating Environment
Description Specification
Recommended Range The limits under which 18°C to 27°C (64.4°F to 80.6°F) and 15°C (59°F) dew point
Operation equipment will operate the most
reliably while still achieving
reasonably energy-efficient
data center operation.
Continuous Allowable Data center economization 5°C to 35°C (50°F to 95°F) at 20% to 80% relative humidity with 21°C (69.8°F)
Range Operation techniques (e.g. free cooling) maximum dew point (maximum wet bulb temperature). De-rate maximum
may be employed to improve allowable dry bulb temperature at 1°C per 300m above 950m (1°F per 547 ft
overall data center efficiency. above 3117 ft).
These techniques may cause
equipment inlet conditions to
fall outside the recommended
range but still within the
continuously allowable range.
Equipment may be operated
without any hourly limitations in
this range.
Improbable Operation During certain times of the 35°C to 40°C (with no direct sunlight on the equipment) at -12°C minimum
(Excursion Limited) day or year, equipment inlet dew point and 8% to 85% relative humidity with 24°C maximum dew point
conditions may fall outside the (wet bulb temperature). Outside the continuously allowable range (10°C to
continuously allowable range 35°C), the system can operate down to 5°C or up to 40°C for a maximum of
but still within the expanded 10% of its annual operating hours. For temperatures between 35°C and 40°C
improbable range. Equipment (95°F to 104°F), de-rate maximum allowable dry bulb temperature by 1°C per
operation is limited to ≤ 10% of 175m above 950m (1°F per 319 ft above 3117 ft).
annual operating hours in this
range.
Temperature Gradient 20°C / hour (36°F / hour)
Altitude Max Operating 3,050m (10,000ft)
Statement of Compliance
Dell Information Technology Equipment is compliant with all currently applicable regulatory requirements for
Electromagnetic Compatibility, Product Safety, and Environmental Regulations where placed on market.
Detailed regulatory information and verification of compliance is available at the Dell Regulatory Compliance website.
https://www.dell.com/learn/us/en/uscorp1/regulatory-compliance