TABLE 9.5.

Lighting Power Densities Using the Building Area Method


Lighting Power Density Building Area Typea (W/ft2)

Automotive Facility Convention Center Court House Dining: Bar Lounge/Leisure Dining: Cafeteria/Fast Food Dining: Family Dormitory Exercise Center Gymnasium Health Care-Clinic Hospital Hotel Library Manufacturing Facility Motel Motion Picture Theater Multi-Family Museum Office Parking Garage Penitentiary Performing Arts Theater Police/Fire Station Post Office Religious Building Retail School/University Sports Arena Town Hall Transportation Warehouse Workshop
a

0.9 1.2 1.2 1.3 1.4 1.6 1.0 1.0 1.1 1.0 1.2 1.0 1.3 1.3 1.0 1.2 0.7 1.1 1.0 0.3 1.0 1.6 1.0 1.1 1.3 1.5 1.2 1.1 1.1 1.0 0.8 1.4

In cases where both general building area type and a specific building area type are listed, the specific building area type shall apply.

64

ANSI/ASHRAE/IESNA STANDARD 90.1-2004

TABLE 9.6.1 Lighting Power Densities Using the Space-by-Space Method


Common Space Typesa Office-Enclosed Office-Open Plan Conference/Meeting/Multipurpose Classroom/Lecture/Training For Penitentiary Lobby For Hotel For Performing Arts Theater For Motion Picture Theater Audience/Seating Area For Gymnasium For Exercise Center For Convention Center For Penitentiary For Religious Buildings For Sports Arena For Performing Arts Theater For Motion Picture Theater For Transportation AtriumFirst Three Floors AtriumEach Additional Floor Lounge/Recreation For Hospital Dining Area For Penitentiary For Hotel For Motel For Bar Lounge/Leisure Dining For Family Dining Food Preparation Laboratory Restrooms Dressing/Locker/Fitting Room Corridor/Transition For Hospital For Manufacturing Facility StairsActive Active Storage For Hospital Inactive storage For Museum LPD (W/ft2) 1.1 1.1 1.3 1.4 1.3 1.3 1.1 3.3 1.1 0.9 0.4 0.3 0.7 0.7 1.7 0.4 2.6 1.2 0.5 0.6 0.2 1.2 0.8 0.9 1.3 1.3 1.2 1.4 2.1 1.2 1.4 0.9 0.6 0.5 1.0 0.5 0.6 0.8 0.9 0.3 0.8 Building Specific Space Types Gymnasium/Exercise Center Playing Area Exercise Area Courthouse/Police Station/Penitentiary Courtroom Confinement Cells Judges Chambers Fire Stations Fire Station Engine Room Sleeping Quarters Post OfficeSorting Area Convention CenterExhibit Space Library Card File and Cataloging Stacks Reading Area Hospital Emergency Recovery Nurse Station Exam/Treatment Pharmacy Patient Room Operating Room Nursery Medical Supply Physical Therapy Radiology LaundryWashing AutomotiveService/Repair Manufacturing Low Bay (<25 ft Floor to Ceiling Height) High Bay (25 ft Floor to Ceiling Height) Detailed Manufacturing Equipment Room Control Room Hotel/Motel Guest Rooms DormitoryLiving Quarters Museum General Exhibition Restoration 1.0 1.7 1.2 1.7 2.1 1.2 0.5 1.1 1.1 2.7 0.8 1.0 1.5 1.2 0.7 2.2 0.6 1.4 0.9 0.4 0.6 0.7 1.1 1.7 1.2 0.8 0.3 1.2 1.3 1.9 0.9 1.3 1.4 0.9 LPD (W/ft2)

ANSI/ASHRAE/IESNA STANDARD 90.1-2004

65